background image

5

aquascapeinc.com 

☎ 

CAN (866) 766-3426 | 

☎ 

US (866) 877-6637

NOTE:

 The unit can also be powered by an existing 12V 

outdoor transformer. Each controller consumes 4.5 watts.

•  Plug the transformer into a GFCI-rated receptacle.

NOTE:

 The unit will add one dose (based on setting) once 

it receives power.

SETTINGS

•  The control panel will default to setting 1. To determine the 

setting for your water feature use the charts on the back of 
each water treatment or visit our website at https://www.
aquascapeinc.com/products/dosing-system-sl

•  Once setting is determined, use the button on the control 

panel to set to recommended setting.

General Maintenance

•  When replacing water treatments, take a few seconds to inspect and, if necessary, clean the tubing of any debris that has 

become trapped in the tubing.

NOTE:

 A soft pipe cleaner, available at most hobby stores, can be used to clean the tubing.

•  The pump cartridge, located on the top of the control panel, is a consumable part that may wear over time, reducing the 

accuracy of the system. It is recommended to replace the pump cartridge once each year (Item #40041).

•  Do not operate at temperatures below 40°F / 4°C as doing so will void the warranty.

PLEASE NOTE:

 Your system and liquid water treatments are not designed to be operated during freezing 

temperatures. The unit is equipped with an internal protection thermostat that will shut off the dosing pump at 
temperatures below 40°F / 4°C. Remove the control panel, treatment, and intake assembly during winter freezing 
temperatures and store in a frost-free location

Troubleshooting

•  The pump does not seem to be pumping the liquid treatment from the bottle into my feature.

 

Make sure the unit is getting power.

 

Make sure the inner tubing and discharge tubing are properly connected and not kinked.

 

Inspect and clean all tubing of water treatment residue using a pipe cleaner

 

Make sure the system is primed. To enter the priming mode, hold the button for 3 seconds. It may take a few minutes for 
the treatment to make its way through the tubing. Refer to page 5 for more information.

 

With priming mode engaged, listen closely, as you should be able to hear the pump turning if it’s working correctly.

 

ƒ

If the pump is not turning when in priming mode, you may need to replace the control panel.

 

If problems persist, it may be time to replace the pump cartridge.

•  Pump does not seem to be pumping accurately.

 

Replace the pump cartridge as explained in General Maintenance.

•  There is no power reaching the unit.

 

Make sure the ground-fault circuit interrupter (GFCI) is not tripped.

 

Check that the transformer is plugged in.

 

Try replacing the transformer; please note that the dosing system uses a 12V low voltage outdoor rated transformer.

PRIMING PROCEDURE

•  When first setting up the system or when adding a new 

water treatment bottle, the system should be primed to 
push the treatment through the output tubing.

•  To enter the priming mode, hold the setting button for 

3 seconds until the blue light below the setting number 
begins to flash. The priming mode will automatically turn 
off when completed returning to normal operation. The 
priming mode can be exited at any time by pressing the 
setting button when the treatment begins to discharge at 
the end of the tubing.

Summary of Contents for 96085

Page 1: ...aquascapeinc com I N S T R U C T I O N S M A I N T E N A N C E DOSING SYSTEM Dosing System SL Item 96085...

Page 2: ...water feature size and enjoy the benefits of clean clear and healthy water This instruction manual will guide you through the proper setup and recommended maintenance to ensure long term enjoyment Th...

Page 3: ...th extension cord D Any wiring of this product should be performed by a qualified electrician to ensure code compliance and user safety E To reduce risk of electrical shock all wiring and junction con...

Page 4: ...encing the indicators on the pump cartridge Ex 7 Connect the inlet tubing to the barb at the top of the intake assembly Ex 8 Choose from four specially formulated pond treatment and two specially form...

Page 5: ...e in a frost free location Troubleshooting The pump does not seem to be pumping the liquid treatment from the bottle into my feature Make sure the unit is getting power Make sure the inner tubing and...

Page 6: ...ginal purchase price The warranty excludes costs of labor removal of product shipping and expenses related to the installation and re installation of the product All products that include plumbing tub...

Page 7: ...aquascapeinc com I N S T R U C T I O N S E T E N T R E T I E N DOSING SYSTEM Dosing System SL R f rence 96085...

Page 8: ...profitez des avantages d une eau propre claire et saine Ce manuel d instructions vous guidera travers la configuration appropri e et l entretien recommand pour assurer un plaisir long terme Nous vous...

Page 9: ...r avec une rallonge D Tout c blage de ce produit doit tre effectu par un lectricien qualifi afin d assurer la conformit au code et la s curit de l utilisateur E Pour r duire le risque de choc lectriqu...

Page 10: ...euvent tre d termin s en se r f rant aux indicateurs sur la cartouche de la pompe Ex 7 Connectez le tube d entr e la cannelure en haut de l ensemble d admission Ex 8 Choisissez parmi quatre traitement...

Page 11: ...onsommable qui peut s user avec le temps r duisant la pr cision du D pannage La pompe ne semble pas pomper le traitement liquide de la bouteille dans mon trait Assurez vous que l appareil est sous ten...

Page 12: ...produit Tous les produits qui incluent la plomberie tuyauterie pompes clapets anti retour doivent tre correctement vidang s et hivern s sinon la garantie est nulle et non avenue Aquascape Inc ou ses...

Reviews: