•  Power cord should be protected by conduit or by cable 

and be of proper gauge. It should be no longer than 
necessary.

•  Power should be drawn directly from a box with circuit 

breaker protection or with a fused disconnect switch.

Pump End Assembly

•  Inspect all pump parts (O-ring, O-ring groove, impeller hub 

ID, motor shaft, etc.) and clean if necessary.

•  Check motor rotation prior to pump assembly.
•  Install threaded rod in end of the motor shaft, leaving

.725

"

± .005

"

 extended beyond the end of the motor shaft. 

Use thread locker to secure in place, let cure overnight.

•  Install motor shaft heat shrink tubing sleeve at this time if 

required.

•  Place slinger over motor shaft.
•  Using a silicon based grease such as Molykote 111

®

lightly grease the OD of the seal head casing/o-ring and 
the pump bracket seal bore. Press the seal head assembly 
into the pump bracket seal bore to stop by applying 
pressure only on the seal casing shoulder (do not press 
on the seal head carbon.), a 1-3/4

"

 socket has the right 

clearance to press on the seal casing shoulder. Wipe away 
any grease squeeze out.

•  Lightly grease the seal seat (mating ring) o-ring and 

impeller hub ID, press the seal seat into the impeller hub to 
bottom, making sure the o-ring has not dislodged and the 
seal seat sits fl at in the bottom of the impeller hub. Wipe 
away any excess grease. Lightly chamfer the impeller cap 
recess.

•  Align the bracket over the motor mounting holes and C 

face. Install bracket/motor mounting bolts and washers. 
Tighten to 75 in. lbs.

•  Place 3/16

"

 square key in motor shaft keyway. If a motor 

shaft sleeve is installed, the end of the square key will slide 
underneath.

•  Clean both seal faces with a lint free tissue and alcohol.

WARNING:

 Do not use grease on the seal faces. 

Slide impeller onto motor shaft aligning key and 
keyways until seal faces touch.

•  Slide the impeller further towards the motor, compressing 

the seal and hold in place while placing rubber impeller 
washer over the threaded rod until it bottoms in contact 
with the motor shaft. Impeller metal washer is next placed 
on top of the rubber impeller washer, lightly grease the 
side of the metal washer that will contact with the rubber 
washer. Lock the impeller in place with the 3/8

"

-16 hex 

jam nut, tighten to 50 in. lbs.

•  Lightly grease the impeller cap o-ring gland, place the 

o-ring in the gland and lightly grease the outside of the 
o-ring and the impeller nose opening. Assemble the 

impeller cap w/ o-ring onto the threaded rod tighten to 50 
in. lbs.

•  Place large o-ring into the o-ring gland in the pump 

bracket, use grease only if required.

•  Assemble volute into position aligning over impeller.
•  Secure volute to bracket using the supplied fi ve

5/16

"

-18 x 4

"

 through bolts with washers, lock washers 

and nuts and three 5/16

"

-18 x 1-1/4

"

 long bolts with 

washers and lock washers into the molded inserts. 
Tighten all bolts to 75 in. lbs.

•  Apply thread sealant to the drain plug threads, tighten to 

seal.

•  Discharge hardware is supplied as it uses non-standard 

(and possibly hard to fi nd) nuts.

Disassembly

•  Shut off power to motor before disconnecting any 

electrical wiring from the motor.

•  Disassemble volute from bracket by removing the fi ve 

5/16

"

-18 x 4

"

 long hex cap screws,  and the three 5/16

"

-

18 x 1.25

"

 hex cap screws.

•  Pump/Bracket/Impeller Assembly may now be pulled back 

from the Volute.

•  Remove impeller eye ‘cap’ by unscrewing 

counterclockwise. Remove impeller locknut, unscrew 
counterclockwise.  Slide impeller off of motor shaft.

•  Remove mating ring from impeller. Eye protection is 

strongly recommended. (If you are replacing the seal)

•  Detach bracket from motor.
•  Remove mechanical seal from bracket by pressing out 

from the back. Do not dig out from the front. (If you are 
replacing the seal).

General Maintenance

•  The pump must be drained before servicing or if stored 

below freezing temperatures. Periodic replacement of seals 
may be required due to normal carbon wear.

•  Lubrication: Rotary Seal - Requires no lubrication after 

assembly.

Summary of Contents for EXT 12000

Page 1: ...U C T I O N S M A I N T E N A N C E aquascapeinc com P R O F E S S I O N A L G R A D E EXT 12000 Pond Pump Item 45049 EXT 18000 Pond Pump Item 45050 EXT 12000 3P Pond Pump Item 45051 EXT 18000 3P Pon...

Page 2: ...late you on your choice of the Aquascape EXT Pond Pumps It has been carefully designed using the advantages of today s technology and carefully constructed to give you the dependability of yesterday T...

Page 3: ...eed an internal case pressure of 100 PSI I Do not wear loose clothing that may become entangled in the impeller or other moving parts J Keep clear of suction and discharge openings DO NOT insert finge...

Page 4: ...e pipe fittings should be self supported and in neutral alignment with each port i e Fittings must not be forced into alignment which may cause premature line failure or damage to the pump volute Neve...

Page 5: ...s the motor compressing the seal and hold in place while placing rubber impeller washer over the threaded rod until it bottoms in contact with the motor shaft Impeller metal washer is next placed on t...

Page 6: ...motor and proper wire size according to local electrical codes Check for foreign material inside pump Remove volute and check for impeller rotation without excessive resistance and or noise Remove pu...

Page 7: ...GPH MAXIMUM OPERATING ZONE BEST OPERATING ZONE DO NOT OPERATE Flow Chart MODEL MAX HEAD HEIGHT APPLICATION HEAD HEIGHT 0 5 10 15 20 25 30 35 40 45 50 12000 21 18000 45 18000 17000 16500 15660 14332 13...

Page 8: ...nd mechanical seals This product should only be operated using fresh water without corrosive chemicals like chlorine or bromine If upon Aquascape s inspection the pump shows evidence of a manufacturin...

Reviews: