background image

4

Fig. 8

Fig. 7

Fig. 9-10

•  Before using the IonGen

, please 

note the following:  
-  If the total alkalinity of the water 

is less than 100 ppm you’ll need 

to increase the level of alkalinity.

-  Alkalinity (not hardness) can be 

determined using the pH/Total 

Alkalinity Test Kit sold separately 

(part #98953).  Alkalinity levels 

outside of the recommended 

parameters will reduce the 

effectiveness of the IonGen

See Targeted Water Parameters 

section for more information

.

•  Start-up of System

-  Turn on the pump.
-  Plug in the IonGen

 and set to 

full power.

-  Perform the copper test per the 

test kit instructions over a period 

of days to ensure that the copper 

levels DO NOT rise above .25 ppm. 

Debris, poor water conditions, 

as well as the volume of water 

feature are all factors that affect 

Operating the IonGen

Operating Instructions

•  Plug in the waterproof connector 

from the Control Panel into the 

top of the Probe fitting.  

(See Fig. 8)

Flow Chamber Option B:

Skimmer or in-stream installation 

The Flow Chamber can be submerged in 

a region of the water feature with a good 

flow of water, such as in a skimmer box 

or the edge of a stream/waterfall. The 

Flow Chamber must be completely sub-

merged and have sufficient water flow 

in order to function properly. The Flow 

Chamber can be camouflaged into the 

edge of the stream using small rocks. 

Failure to provide sufficient water flow 

across probe will affect the IonGen’s

 

performance. 

See troubleshooting Table 

for more information.

 Note:

 

Completely 

remove Probe from water when con-

necting or disconnecting the waterproof 

electrical plug.

  

(See Fig. 9 and 10)

Power Indicator 

– The Power indicator light will be 

illuminated when the Control Panel is receiving power.

Choosing Desired Ionization Level 

– The amount of ions being 

generated can be controlled using the up and down button. The lighted 
ionizing indicator bar will display the output level of the generator.

Ionizing Indicator 

– The Ionizing indicator light will be SOLID GREEN 

when the generator is properly ionizing. The ionizing indicator light will be 
FLASHING GREEN when the generator has reached its maximum output. 

See 

Troubleshooting Table for more information on how to increase the generator’s 

output.

 The ionizing light will flash RED when the Probe is exhausted or 

the Control Panel indicates a problem. 

See Troubleshooting Table for more 

information on the RED Ionizing light.

•  The Replaceable IonGen

 Probe 

will typically last 1 -3 seasons 

depending on the usage, quantity of 

Maintenance

Note:

 The red dot on the top of 

the probe fitting indicates proper 

orientation of the probe when 

installed into the Flow Chamber. 

Make sure the red dot is lined up 

with the direction of the water 

flow through the Flow Chamber. 

Proper orientation of the probe 

will maximize the IonGen’s

 

performance.

 

(See Fig. 4-7)

water and water parameters of the 

water feature. The Ionizing Indicator, 

which is normally lit GREEN when 

ionizing, will begin to flash RED. The 

flashing RED ionizing light indicates 

when the Probe is exhausted  

or there is a problem with the 

IonGen

See Troubleshooting  

Guide for more information on  

the RED Ionizing light. 

the speed at which the IonGen™ 

will achieve desired results and 

the level of copper in the water 

feature. 

Please note that it 

may take several weeks before 

the copper level begins to be 

detectable.

-  The IonGen’s

 ionization level  

can be reduced to show 1 or 2 

bars on the Ionizing Indicator 

Display once desired results are 

achieved with the appearance of 

the water conditions in the water 

feature or the copper test strips 

indicate the maximum level of  

.25 ppm. If alkalinity is more 

than .25 ppm it can be typically 

reduced by conducting a partial 

water change. 

-  Operating the IonGen

 at a low level 

and only raising the ionization 

level based on the appearance of 

the water conditions will prolong 

the life of the probe, as well as 

help make sure copper levels 

don’t become too elevated. 

Note:

 It is not unusual to have low 

copper level readings on the test 

strips, no matter how high the 

IonGen’s

 ionization level setting. 

This is due to the copper being 

used within the water feature. 

Periodic copper testing will ensure 

that the levels stay below .25 ppm.

 

-  If the level of copper is allowed 

to go above .25 ppm reduce the 

IonGen

 down to one bar on 

the Ionizing Indicator Display or 

unplug the IonGen

 until the 

copper levels fall below .25 ppm. 

A water change can also be 

conducted if the copper levels are 

significantly above .25 ppm. 

(See 

Fig. 11).

-  In the case of a power failure the 

IonGen

 Control Panel’s internal 

memory will reset itself to the last 

setting before the power failure.

Fig. 11

Summary of Contents for IonGen

Page 1: ...n Installation Instructions Maintenance Owner s Manual Made in U S A Aquascape Inc St Charles IL 60174 Brampton ON L6T 5V7 www aquascapeinc com Electronic Clarifier for Ponds and Pondless Waterfall Sy...

Page 2: ...polarity to prevent scale and debris build up on the Probe s bars The metal alloys in the Probe are scientifically blended and tested to produce maximum results The IonGen when used according to the...

Page 3: ...g the replaceable Probe and overwintering the fitting It is recommended to use a pre filter such as a skimmer prior to the Flow Chamber in order to remove solids and debris that may interfere with the...

Page 4: ...s output The ionizing light will flash RED when the Probe is exhausted or the Control Panel indicates a problem See Troubleshooting Table for more information on the RED Ionizing light The Replaceable...

Page 5: ...Flow Chamber Increase pump run time or move Flow Chamber to higher flow location Debris stuck on Probe Remove Probe and clean debris and any scale build up off bars Outside of targeted water parameter...

Page 6: ...y Serial Number or S N is located on white label on cord Manufacture setting in Control Panel needs to be adjusted Remove back panel of Control Panel and turn the blue potentiometer screw clockwise un...

Page 7: ...e passion 7 Guide d installation et manuel d utilisation Fabriqu aux tats Unis Aquascape Inc St Charles IL 60174 Brampton ON L6T 5V7 www aquascapeinc com Clarificateur lectronique pour bassins et casc...

Page 8: ...ent l entartrage et l accumulation de d bris sur les lectrodes L alliage m tallique des lectrodes est scientifiquement dos et test pour donner des r sultats optimaux Le clarificateur IonGenMC lorsqu u...

Page 9: ...o il y a un bon d bit d eau comme dans le bo tier de l cumoire ou le bord d une cascade Assurez vous que le connecteur des lectrodes atteigne la chambre d ionisation Suivez le guide tape par tape pou...

Page 10: ...que les taux de cuivre demeurent sous 0 25 ppm Si la concentration de cuivre d passe 0 25 ppm r duisez le clarificateur IonGenMC une barre sur le voyant d ionisation ou d branchez le jusqu ce que les...

Page 11: ...Remplacez une partie de l eau par de l eau fra che pour faire baisser plus rapidement la concentration de cuivre 7 L eau est trouble importante quantit de d bris D bit d eau insuffisant dans la chambr...

Page 12: ...trois saisons selon l usage qui en est fait la quantit d eau traiter et les param tres de l am nagement aquatique Le voyant d ionisation qui est normalement au VERT se met clignoter en rouge lorsqu i...

Reviews: