background image

Document Created by: 

Sikich Graphic Design & Marketing Services

Document Creator Contact Information:

Sikich Graphic Design & Marketing Services
1300 Iroquois Ave., Suite 260
Naperville, IL 60563
p 630.717.7515
f 630.717.7150

Document Designer:

Rick Byers

Client

Aquascape, Inc.

Designer E-Mail:

rbyers@sikich.com

Client Contact

Scott Rhodes

Icon Job Number:

11088796

Client Contact E-Mail

srhodes@aquascapeinc.com

Number of Colors

1/1

Client P.O. Number

110141

Number of Pages

8

Client Job Description:

39000 Pond De-Icer 300-Watt Instructions 08-11

Flat Size

 (W x H)

17” x 11”

Folded Size

 (W x H x D)

8.5” x 11”

www.aquascapeinc.com

Pompe submersible 

pour fontaine, 

cascades et filtre

Pour les modèles suivants :

 400 (article n

o

 91005)

 550 (article n

o

 91006)

 800 (article n

o

 91007)

 1100 (article n

o

 91008)

 1500 (article n

o

 91009)

 2000 (article n

o

 91010)

Disponible en débits  

de 1514 à 7570 L/h

Ultra

MC

 400/550/800/1100

Ultra

MC

 1500/2000

ULTRA

MC

WATER PUMP

YE

AR 

WARRAN

TY

G

AR

ANTIE DE 3 A

N

S

3

I N S T R U C T I O N S   E T   E N T R E T I E N

91054 - 91005, 91006, 91007, 91008, 91009, 91010 Ultra Pump Instructions D7.indd   9

10/3/14   3:12 PM

Summary of Contents for Signature series 400

Page 1: ...mp For Models 400 Item 91005 550 Item 91006 800 Item 91007 1100 Item 91008 1500 Item 91009 2000 Item 91010 Available in flow rates from 400 to 2000 GPH I N S T R U C T I O N S M A I N T E N A N C E Ul...

Page 2: ...efective No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is assumed by Aquascape Inc or its affiliates Co...

Page 3: ...r 8 1 1 Multi Hose Adapter 9 Barb Valve 1 Front Cover 2 Filter Sponge 3 Water Chamber Assembly 5 Impeller Assembly 5 Rubber Feet 6 Main Housing 7 Back Cover 8 x 1 1 Multi Hose Adapter 9 3 way Valve 10...

Page 4: ...o lift pump Installation Always operate the pump fully submerged Failure to do so will overheat the pump and cause it to fail thus voiding the warranty DO NOT OPERATE DRY Use only in fully assembled s...

Page 5: ...ative fountain container To maximize pond circulation locate the pump as far away as possible from the location of the water entering back into the water feature Pond with external filter Decorative F...

Page 6: ...tected by a ground fault interrupter Once the pump is running and water is circulating through the filter s or waterfalls check for any fitting or waterfall leaks where the external connections are ma...

Page 7: ...ler Kits are available through your local Aquascape dealer 1a Note the orientation of parts in the photo below The replacement impeller kits include all parts shown Make sure to remove all of the orig...

Page 8: ...rotor assembly and internal pump body Make sure nothing is blocking or wrapped around the impeller Make sure the pump is receiving the correct voltage Pump Not Working The ground fault circuit interru...

Page 9: ...no 91005 550 article no 91006 800 article no 91007 1100 article no 91008 1500 article no 91009 2000 article no 91010 Disponible en d bits de 1514 7570 L h Ultra MC 400 550 800 1100 Ultra MC 1500 2000...

Page 10: ...uts dans les mat riaux et les d fauts de fabrication seulement Le remplacement de l unit d fectueuse par une unit de rechange appropri e sera la seule obligation Les unit s devront tre v rifi es afin...

Page 11: ...usqu 86 36 cm Jusqu 55 88 cm Jusqu 218 44 cm UltraMC 2000 91046 Jusqu 91 44 cm Jusqu 60 96 cm Jusqu 243 84 cm Cloche d eau Jet moussant Fontaine marguerite Trousse de t tes de fontaines Mod le de pomp...

Page 12: ...son utilisation sinon elle pourrait surchauffer entra nant ainsi sa d faillance et annulant de ce fait la garantie NE FAITES PAS FONCTIONNER LA POMPE SEC Utilisez seulement lorsque la pompe est enti r...

Page 13: ...lan d eau ou une fontaine d corative La pompe UltraMC est con ue pour tre submerg e directement dans le plan d eau ou le r servoir de la fontaine d corative Pour maximiser la circulation d eau dans le...

Page 14: ...filtration de la pompe Dans de nombreux cas la cage de filtration bouch e peut tre nettoy e en plongeant la main dans la pompe et en retirant manuellement les d bris de la cage de filtration S il y a...

Page 15: ...ontre au del des indicateurs et en tirant pour le d loger Ceci exposera l assemblage de la turbine pour une meilleure inspection Enlevez soigneusement la turbine de la pompe tout en prenant garde de n...

Page 16: ...uvercle du r servoir inspectez et nettoyez l assemblage du rotor de turbine et la partie interne de la pompe Assurez vous que rien ne bloque ou n est envelopp autour de la turbine Assurez vous que la...

Reviews: