THE FOLLOWING SECTIONS REGARDING PROGRAM OPERATION ARE
ONLY APPLICIABLE WHEN USER SCROLLS TO THE PROGRAM MODE.
The AQUA SMART™ can operate from a factory-installed program or one entered by
the user. A description of both these programs follows with reprogramming instructions.
FACTORY-SET PROGRAM – The transmitter has a factory-set program that has been
encrypted into the software with factory-set, ON-OFF settings to operate the water
heater. This factory-set program will operate ONLY when in the PROGRAM mode, and
will be overridden when a user enters his personal program. The factory –set program
is displayed below:
FAC FACTORY-SET PROGRAM
MODE ON (TEMP. SETTING) OFF (TEMP. SETTING)
MORN: 5:00 am (120°F) 8:00 am (75°F)
DAY: 4:00 pm (120°F) 6:00 pm (75°F)
NITE: 7:00 pm (120°F) 9:00 pm (75°F)
The temperature for the ON setting is 120°F. However, if the “on board” thermostat
settings on the users’ hot water heater are higher than 120°F, the software commands
the system to “default” to the “on board” thermostat setting on the water heater. For
safety purposes, this setting should be at 120°F. However, it could be higher if the user
has set the “on board” thermostats to a higher temperature, but only 120°F will show on
the LCD.
The temperature for the OFF setting is 75°F. When the water temperature drops to
75°F, the water heater is “powered” and shuts off at 80°F.
Review the matrix/protocol for the ON - OFF temperature settings and the “triggering
spreads” between ON - OFF at the end of this manual. (See pages 36-37).
IMPORTANT NOTE: The FACTORY –SET program settings may not match with the
user’s daily activities and reprogramming, by the user, may be necessary. User
programming instructions are covered on pages 27-29.
26.
PROGRAM OPERATION OF THE AQUA SMART™ SYSTEM – (continued)
USER-SET PROGRAMMING PROCEEDURES- User may change the following
settings, but only in the PROGRAM mode. Below is a list of “user” program
settings.
·
PERIODS OF THE DAY: MORN DAY NITE
(For each DAY OF THE WEEK: S - M - T - W - T - F - S)
·
HOUR OF DAY WITHIN EACH PERIOD
·
ON - OFF TEMPERATURE SETTINGS WITHIN EACH PERIOD
User can program the daily operation of the AQUA SMART™
system following the programming procedures below.
1. Press and hold the PROGRAM button for
more than 5 seconds. The shaded boxes
with the PROGRAM FOR and HEATER
words will begin blinking and the word, ON,
will display. (S, MORN, 5:00AM, °F and
120°F will also be displayed).
NOTE: The INITIAL SET-UP procedures
must have been previously entered or the
user programming cannot be continued.
2. To program the PERIOD and DAY for the
heater to go ON, press the UP/DOWN
buttons scrolling through the PERIODS.
(The days will advance as you scroll
through the periods). When the PERIOD
and DAY are selected, press the
PROGRAM button. The PROGRAM FOR
and HEATER words will stop blinking and
the word, ON, and the HOUR digit will begin
blinking.
3. To set the HOUR for the heater to go ON,
press the UP/DOWN buttons, adjusting the
time, in full hour increments. Press the
PROGRAM button to set the HOUR and the
SENSOR TEMP SET temperature will begin
blinking.
27
.