4. To set the water TEMPERATURE for
the heater to go ON, press the UP/DOWN
buttons to program water heater to go ON
at the time entered in step 3.
Press the PROGRAM button again and
the word, OFF, and the HOUR digits will
begin blinking.
5. To set the HOUR for the water heater
to go OFF, press the UP/DOWN buttons,
adjusting the time, in full hour
increments and press the PROGRAM
button to set the HOUR. The SENSOR
TEMP SET temperature will begin
blinking.
6. To set the water TEMPERATURE for
the heater to go OFF, press the
UP/DOWN buttons to program water
heater to go OFF at the time entered in
step 5. Press the PROGRAM button again
and the PROGRAM FOR and HEATER
words will begin blinking.
The next PERIOD and the next DAY will
advance after programming the NITE
period.
The PROGRAM FOR and HEATER
words will begin blinking.
7. To set the next DAY & PERIOD, press
the PROGRAM button again and then
repeat steps 2-7 to complete the user
programming process.
8. At the end of the user programming
process, press the SET button to “lock in”
the new “user program”.
28.
IMPORTANT NOTE: User settings are limited to between 75°F and 120°F. The
lowest temperature for the OFF setting is 75°F. When the water temperature drops
to 75°F, the water heater is “powered” and shuts off at 80°F. The highest OFF
temperature setting is 120°F.
MATRIX - PROTOCAL TEMPERATURE RESTRICTIONS
When user SETS a temperature to ON, user can also set the OFF temperature, however, the
setting for the OFF temperature can be no less than 10°F from the ON temperature setting.
Review the matrix - protocol charts for the ON - OFF temperature settings and “triggering
spreads” between ON - OFF on pages 36-37.
Temperature settings between the 75°F and 120°F will operate within a 5°F temperature
spread/swing. (See page 37).Should user want to set lower temperatures, user can activate the
VACATION mode but will have to remember to return to another mode for higher temperatures
.
7. PROGRAM REVIEW: To review
program settings, enter a short push of the
PROGRAM button which enables user to
review either the factory-set or user-set
PROGRAM settings. Then, continue to
enter short pushes on the PROGRAM
button to review all the programmed
settings. Press SET button when review
completed.
CHANGING/CANCELLING PROGRAMS: User may change the factory-set program by
following the procedures as outlined in steps 1-6. Should user wish to return to the factory-set
program, PUSH and HOLD the UP and PROGRAM buttons, at the same time for more than 5
seconds, and user-set program is cancelled and the system reverts back to the factory-set
program. The transmitter will emit 4 short beeps confirming the cancellation step.
8. OVERRIDE: The OVERRIDE
feature only operates in the PROGRAM
mode. User may change the current
SET
TEMPERATURE
in
the
PROGRAM mode without changing the
other programs stored in the transmitter.
When in the PROGRAM mode, user
can push UP/DOWN buttons to change
factory-set
and/or
user-set
TEMPERATURE settings, in single
digits.
The word OVERRIDE will appear on the LCD and the OVERRIDE feature activates. The
OVERRIDE setting will be automatically cancelled at the start of the next PROGRAM PERIOD
.
29.