background image

5

AQUASURE 

FORTITUDE PRO SERIES

STEP 2. 

Shutting off the Main Water Supply Valve

1.  Locate the main water supply valve of the house and turn off completely by turning the 

shut-off handle clockwise.

2.  Test to see if the water is completely shut off by turning on the faucet in the cold water 

position. If the cold water cannot be shut off, please contact your local plumber to fix the 
valve before begin installing the system. 

IN

STEP 1. 

Checking the direction of the water flow

1.  Make the water flow to make sure they are going from left to right or right to left. 
2.  Reassemble the mounting bracket for the pleated sediment filter if the direction is 

oppsite of where the mounting bracket is facing. 

3.  Make sure the flow fo the water goes into the opening that indicated “IN” on top of the 

CAP and exit from the opening that indicated “OUT”. 

IN

Summary of Contents for AS-FP1000

Page 1: ...FORTITUDE PRO SERIES WHOLE HOUSE WATER FILTER OWNER S MANUAL FOR MODEL NO AS FP600 AS FP1000 AS FP1500...

Page 2: ......

Page 3: ...YSTEM STEP 1 Checking the Direction of Water Flow STEP 2 Shutting off the main water supply valve STEP 3 Mounting the 20 High Flow Sediment Filter STEP 4 Attaching the water supply pipe STEP 5 Install...

Page 4: ...en or Pencil System Components Breakdown 20 Pleated Sediment Filter Parts Aquasure High Flow Housing X 1 AP FWRENCH Aquasure Fortitude V Series Housing Wrench X 1 AP F1BRACKET Aquasure Single Housing...

Page 5: ...40 F 4 4 C 2 Water Pressure Parameter Maximum 75 PSI 5 98 kg cm2 Minimum 20 PSI 1 41 kg cm2 3 pH Parameter Maximum 10 Minimum 5 4 Pre install environment checklist Do not use with water that is microb...

Page 6: ...ly grounded appliances downstream or potential galvanic activity in the plumbing system can no longer ground through contiguous metal plumbing Some homes may have been built in accordance with buildin...

Page 7: ...cannot be shut off please contact your local plumber to fix the valve before begin installing the system IN STEP 1 Checking the direction of the water flow 1 Make the water flow to make sure they are...

Page 8: ...tion the system on the wall at the desired mounting location with minimum of 6 in ground clearance from the floor to the base of the system 2 Using a pen or pencil and mark the mounting hole on the ba...

Page 9: ...g STEP 6 System Startup WARNING Immediately shut off the main water supply valve if there are leaks Check the leak area and see if there s a loose connection or if more Teflon tape is needed to preven...

Page 10: ...ment and shall be limited to the repair or replacement of only the specific Product that fails due to a manufacturing defect Any repaired or replaced product shall also remain subject to the original...

Page 11: ...oduct or parts of the product or at the option of Aquasure return of the product and a refund of the purchase price Buyer assumes all risk whatsoever as to the result of the use of the product purchas...

Page 12: ...www AquasureUSA com 818 N Mountain Ave 203c Upland CA 91786 800 661 0680 sales aquasureusa com...

Reviews: