20
www.
AQUASURE
USA
.com
Tel: 1-800-661-0680
TOTAL GALLONS CALCULATION
The Aquatrol valve uses a meter to count the gallons of water being treated through the system. Once the gallons
programmed in the unit has been exhausted, the system will regenerate. The total gallons of treatable water the system
can produce is based on the system size, family size, and the hardness level of the feed water. A simple calculation is done
to determine the amount of gallons to input during the programming portion of the installation.
NOTE: This calculation must be completed to program the unit:
Example:
System Capacity: AS-HS32D System/32,000 Grains (chart above)
Feed Water Hardness: 25 GPG (must be tested on-site by the end user or installer)
Number of People: 3
(32,000 Grains / 25 GPG) - (3 People X 75 Gallons) = Total Gallons
1,280 Gallons - 225 Gallons = 1,055 Total Gallons
1,055 Gallons would be inputted for Total Gallons during programming.
If the hardness level is given in ppm or mg/L, it can be converted to Grains Per Gallon by dividing the value by 17.1.
Input the site values in the equation below to figure out your total gallons value:
Total Gallons = System Capacity in Grains (see chart below) / Hardness in (GPG) Grains Per Gallon
(determined by water test) - Number of People X 75 Gallons
( __________Grains / __________GPG) - ( __________ People X 75 Gallons)
__________Gallons - __________Gallons = __________ Total Gallons
Parameter
Aquasure Water Softener
AS-HS32D
AS-HS48D
AS-HS64D
Medium Salt Curve Capacity Setting
32,000
48,000
64,000
Brine Fill Settings in Minutes
6
8
10