23
AQUASURE
HARMONY SERIES
The display shows as:
The system will show the status
when power failure after find the
position.
Queued Regeneration
When the valve is in service position press the button to activate the queued regeneration.
Queued Regeneration means the system will initiate a regeneration at the time set. If missed, it will initiate on the next day.
1) Pull out the power
2) Press the button and plug in the power simultaneously
3) Release the button
The system is now restored
11:30
0 2 : 1 8 - - - -
11:30
R E S E T
11:30
R E S E T
Flashing
Flashing
Flashing
Alternating
Display
11:30
0 2 : 1 8 - - - -
Flashing
11:30
0 2 : 1 8 - - - -
11:30
6 0 M 3
5. Manual regeneration
3. Memory during power failure
4. Restore factory settings
The display shows the Queued Regeneration
in TIMER Mode
The display shows the Queued Regeneration in Meter Delay Mode.
The system will initiate a regeneration - either the treated water remaining counts down to zero or the remaining time counts
down to zero, whichever is first.
The display shows the Queued Regeneration
in Meter Delay Mode
All program settings are stored in permanent memory. Current valve position, cycle step elapsed, time of day are stored during the
power failure. Reset the current time is necessity when power up.
If the valve stopped at a regeneration stage when power failure, the valve will return to prior position when power up. It takes 4 to 5
minutes to reset to the position.