CAUSE:
CORRECTION:
A
Automatic shut-off valve is defective
Test the functionality of automatic shut-off valve by
closing the tank ball valve to see if the system will
shut off. If the system continues producing water, the
automatic shut-off valve is defective and needs to be
replaced.
B
Automatic shut-off valve is not defective and
incoming water pressure is too low
Incoming water pressure must be above 40 psi. Install
a booster pump or permeate pump.
C
System is feeding multiple outlets or an outlet
that demands water constantly.
It is normal in this situation as system needs to
constantly produce water to supply the multiple
outlets.
11. System does not shut off