II. System Operation Parameter and Installation checklist
IMPORTANT!
The following condition for feed water supply must be met or warranty will be
void and manufacturer assumes no responsibility for damage to system or property.
1.
Water Temperature Parameter
•
Maximum: 100º F (37.8º C)
•
Minimum: 40º F (4.4º C)
2.
Water Pressure Parameter
*Pressure reducer recommended if PSI exceeds 75 psi.
•
Maximum: 75 PSI (5.98 kg/cm2)
•
Minimum: 20 PSI (1.41 kg/cm2)
3.
pH Parameter
•
Maximum: 10
•
Minimum: 5
* A vacuum breaker may be needed for well water installation.
4.
Pre-install environment checklist
•
Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
•
Filtration system must not be installed at an area where it is exposed to direct sunlight
and must be protected against freezing and extreme heat.
•
To prevent possible water damage, high flow housing should be replaced every 4 years.
Recommended Tool List for System Installation
•
Variable Speed Drill
•
Drill Bit
•
Bolt Bit
•
Adjustment Wrench
•
Level Tool
•
Teflon Tape
•
Pen or Pencil
Recommended Parts List for System Installation
•
1” Male Thread Adapter X 4
•
1” Shut Off Valve X 3