9
ELECTRICAL REQUIREMENTS
CONFIGURING SYSTEM
SELECTING THE SUPPLY VOLTAGE FOR YOUR SPA
Your spa is designed to operate at either 110V 15 amp; 110V 30 amp, or 230V 50 amp circuit.
• When the spa is setup for 110V 15 amp, the heater will provide approximately 1000 watts of
heat only when the pump is operating in LOW speed and the thermostat is calling for heat
(NOTE: The heater does not operate when the pump is on high speed).
• When the spa is connected to 110V 30 amp, the heater will provide approximately 1000 watts of
heat when the pump is operating in LOW or HIGH speed and the thermostat is calling for heat.
• When the spa is connected to 230 volts, the heater will provide approximately 4000 watts of
heat when the pump is operating in LOW or HIGH speed and the thermostat is calling for heat.
All electrical connections must be made in accordance with the wiring information contained on
the electrical control box cover and the National Electrical Code.
110 VOLT INSTALLATION
(CORD CONNECTED)
Spas come with a factory-installed power supply GFCI cord and are to be plugged into a grounded
type 110 volt, 15 amp receptacle. No other electrical appliance or fixture can be used on this circuit.
IMPORTANT:
Under
NO
circumstances should an extension cord be used. Use of an extension
cord will seriously degrade the performance of the equipment and can create an electrical hazard
and void the warranty.
110 VOLT 30 AMP OR 230 VOLT 50 AMP
(PERMANENT FIELD CONVERSION)
• A 110 volt, 30 amp configuration requires a 30 amp GFCI Subpanel box (not included).
• A 230 volt, 50 amp configuration requires a 50 amp GFCI Subpanel (not included)
Either one of these installation requires a licensed electrician.
Field Converted 110V 30 AMP Control Box
Field Converted 110/230V Control Box
IMPORTANT:
After powering up the spa on 110V 30 amp or 230V 50 amp field conversions,
a
program configuration is required.
Press and Hold JETS button for 30 seconds to access the
Low Level (LL) settings on the control panel. Use the +/- button to change the setting from LL1
Factory Default (non concurrent heat and high speed) to LL2 (concurrent Heater and High Speed
pump) configuration. Press the LIGHT button within 25 seconds to save the new program setting.
To convert, remove the cord from the
terminal block and replace with White,
Black and Green #10 wires and connect
to 30 amp GFCI Subpanel.
Subpanel
White
Green
Black
Subpanel
White
Green
Black
Red
To convert, remove the cord and brown
jumper wire from the terminal block. Remove
other end of brown wire from connector and
remove from box. Place Red, White, Black
and Green #8 wires onto terminal block and
connect other end to 50 amp GFCI Subpanel.
Summary of Contents for Aryana
Page 1: ...OWNER S MANUAL 110V 230V 60Hz Models 303556 21 A 9 20 ...
Page 48: ...MANUAL DEL PROPIETARIO Modelos de 110 V 230 V 303556 21 A 9 20 ...
Page 49: ...MANUAL DEL USUARIO Modelos de 110 V 230 V 60 Hz 303556 21ES A 9 20 ...
Page 73: ...MANUEL DU PROPRIÉTAIRE Modèles 110 V 230 V 60 Hz 303556 21FR A 9 20 ...