13
CONTROL PANEL OPERATION
FAHRENHEIT/CELSIUS SETTING
To change water temperature display to either Fahrenheit or Celsius, press and hold
Light
button for 5
seconds until F1... is displayed. Press the
Light
button several times until F or C is displayed. Press the
Plus
or
Minus
button to change. Wait 15 seconds to allow the exit timer to expire and store the setting.
SMART WINTER MODE
The Smart Winter Mode (SWM) is used to prevent water from freezing in the plumbing of the spa.
As soon as there is a risk of freezing, this protection automatically kicks in. The SWM protection
will turn back off only after 24 hours without a risk of freezing. During this 24 hour period, the
Smart Winter Mode icon remains on; the icon blinks when the purge is active..
DIAGNOSTIC LCD MESSAGE
Message Meaning
Action Required
No message on display.
Power has been cut off to the spa.
The control panel will be disabled until power
returns. Spa settings will be preserved until
next power up.
HL
The system has shut the heater
off because the temperature at the
heater has reached 122°F (50°C).
Do not enter the water!
DO NOT ENTER THE WATER. Remove the
spa cover and allow the water to cool down,
then shut power off and power your spa up
again to reset the system.
If spa does not reset, shut off the power to the
spa and call Customer Service.
AOH
Temperature inside the equipment
compartment is too high 194°F
(90°C), causing the internal
temperature in the control system to
increase above normal limits.
Open equipment compartment and wait until
error clears.
PRR
A problem is detected with the
temperature probe.
Call your Dealer or service supplier.
OH
The water temperature in the spa
has reached 108°F (42°C). Do not
enter the water!
Remove the spa cover and allow the water to
cool down to a lower temperature. Call your
Dealer or service supplier if problem persists.
UPL
No low level configuration software
has been installed into the system.
Call your Dealer or service supplier.
FLO
No water flow is detected by the
control system but flow is expected.
Make sure that the jet pump is running and
water is flowing; check and clean filters; make
sure water valves are open; make sure spa
has a proper water level. If problem persists,
call your Dealer or service supplier.
WARNING! DO NOT ENTER SPA IF WATER IS TOO HOT
Water is too hot.
Overheat protection heater is deactivated. Spa water temperature is above
acceptable limits. When the actual water temperature is approximately 2º F (1º C) above the
set temperature, the jet pump will stop operating to reduce (frictional) heating. If the spa water
temperature continues to rise and gets above 108º F (42ºC), the spa will go into an “OH” overheat
condition.
Summary of Contents for Aryana
Page 1: ...OWNER S MANUAL 110V 230V 60Hz Models 303556 21 A 9 20 ...
Page 48: ...MANUAL DEL PROPIETARIO Modelos de 110 V 230 V 303556 21 A 9 20 ...
Page 49: ...MANUAL DEL USUARIO Modelos de 110 V 230 V 60 Hz 303556 21ES A 9 20 ...
Page 73: ...MANUEL DU PROPRIÉTAIRE Modèles 110 V 230 V 60 Hz 303556 21FR A 9 20 ...