background image

— 8 —

Aquatic Bath • 8101 E. Kaiser Blvd., Anaheim, CA • (800) 945-2726 • www.aquaticbath.com

Installation Data

160304PSL/R, 160304PSML/R,  

260304PSL/R, 260304PSML/R

Fax on Demand # 9034

Clean-up

 
CAUTION: DO NOT USE heat or solvent based cleaning
fluids. NOTE: Do not remove warranty/maintenance adhered
label. Warranty/User maintenance label must be left for
occupant (Required by ANSIZ124).

1.

    Prevent staining. Remove all debris before plumbing leak  

test. Drain and wipe clean immediately after the inspection process. 
Use sponge with warm water and liquid detergent. Rinse, drain 
and wipe clean. Do not use abrasive cleansers such as scouring 
powders, steel wool, metal scrapers, sandpaper or anything else 
that might mar, dull or scratch  
the finish. Roofing tar or paints may be removed with rubbing 
alcohol or paint thinner (not lacquer thinner).

2.

   Plaster and latex paint may be removed with warm water, liquid 

detergent and brittle brush or plastic scraper. Do not  
use metal scraper or utensil to remove plaster or paint  
from finish.

3.

   Dull areas and light scratches can be restored to high  

gloss with white or cream-colored automotive rubbing compound, 
followed by application of coat or good quality white automotive 
polish (or similar) and buff with a soft cloth. 

DO NOT WAX

 

standing surfaces of the unit bottom (this includes textured, slip 
resistant standing surfaces), which  
could result in greater risk of slipping and personal injury. 

4.

   Major gouges require professional repair.

5.

   See user maintenance label for more details.

User Maintenance Instructions

IMPORTANT! Use only recommended cleaners and
procedures described herein. Use of other materials and
methods may damage your bath fixture and void the
warranty.

1.

   For normal cleaning, never use abrasive cleaners such as scouring 

powders or pads, steel wool, scrapers, sandpaper  
or anything else that could scratch or dull the surface of your Aquatic 
unit. Instead, use warm water and liquid detergents 
or non-abrasive cleansers, especially those bathroom 
cleansers recommended for fiberglass.

2.

   To keep your Aquatic bath fixture sparkling clean, apply a 

coat of good quality automotive paste wax or polish and buff 
to a high shine with a soft cloth or towel. Repeat every six 
months for easier cleaning and long lasting protection. 

DO 

NOT WAX

 standing surfaces of the unit bottom (this includes 

textured, slip resistant standing surfaces), which could result 
in greater risk of slipping and personal injury.

3.

   To restore a scratched or dull unit, use an automotive 

polishing compound applied with a clean cotton rag. Rub 
scratches and dull areas vigorously. Wipe off residues. 
Follow with automotive wax treatment described above. 

DO 

NOT WAX

 standing surfaces of the unit bottom (this includes 

textured, slip resistant standing surfaces), which could result 
in greater risk of slipping and personal injury.

4.

   To remove adhesive, try 3-M® natural cleaner, De-Solv-It® or 

similar materials. If residues remain, saturate small white 
cotton rag with nail polish remover and rub vigorously until 
the adhesive dissolves and disappears. These solvents are 
highly flammable and must be used sparingly and with 
caution. Do not allow solvent to go down the drain. Make 
sure not to contact plastic drain grates or other synthetic 
materials.

5.

   Rubber mats: If you use rubber “anti-skid” mat, make sure to 

remove it from the unit after each use to avoid harm to the 
surface finish.

6.

   Hard Water: Water in certain regions, if not wiped up after 

bathing/showering, may cause fading of some bath fixture 
colors. This is a natural occurrence beyond Aquatic’s control. 
(See Warranty)

CAUTION: When using any cleaning or polishing materials,
make sure to read and follow all package instructions
carefully. Wear rubber gloves at all times and avoid contact
with eyes, skin, clothing, rugs and furnishings. Make sure all
residues are rinsed off thoroughly.

Summary of Contents for 160304PSL/R

Page 1: ...l instructions prior to installing your Aquatic Bath fixture Save these instructions for future reference Failure to comply with these instructions may invalidate your warranty For questions concerning installation and maintenance of your Aquatic Bath shower or tub shower contact Technical Services at 800 945 2186 Installation Data 160304PSL R 160304PSML R 260304PSL R 260304PSML R Fax on Demand 90...

Page 2: ...r foundation material may be required for additional support if subfloor is uneven 7 Provide 6 150mm diameter floor opening for 2 50mm IPS and drain connection for shower or a 6 x 12 floor opening for tub 8 Make sure all plumbing is complete and to code 9 To avoid obstruction make sure that supply lines and valve plumbing do not project into framing pocket during the installation process 10 On ins...

Page 3: ...es Stud can be turned for easier installation 6 x12 A A A A C C D D B B 1 1 6 1 2 C L 2 2 Level and mark all sides Front apron should be firmly on the floor NOTE If unit is not level the joints and seams will not align properly 4 4 Lift and place the back wall 5 5 Lift and place the base into framing 3 3 Models A B C D 6030SPAN 6030SPANM 60 1 8 1527mm 31 1 4 794mm 8 1 2 216mm 14 1 4 362mm 6030STUB...

Page 4: ...l side wall and base 10 10 Slide side wall into position 7 7 Mark location of plumbing on shower wall Refer to Shower Mounted Fitting section for measurements 9 9 Using a hole saw fine tooth or abrasive grit cutting edge make necessary openings for filler and valves drilling from inside smooth side out 11 11 Installation Data 160304PSL R 160304PSML R 260304PSL R 260304PSML R Fax on Demand 9034 ...

Page 5: ...laster to displace and spread 14 14 Tap down until level Level lengthwise and widthwise using 3 ft 915mm level by shimming or depressing foundation materials The unit must be set level Apron should be firmly on the floor 16 16 Fasten a 1 x 3 25mm x 75mm ledger strip along rear of alcove and along both sides immidiately below the lower marks made on framing 13 13 Place base into framing pocket 15 1...

Page 6: ... each corresponding stud Pre drill both vertical side flanges and fasten to side studs 8 200mm on center 21 21 Check for level Shim if necessary 23 23 Level back wall vertically horizontally Shim if necessary 20 20 Apply silicone along horizontal and inside vertical edge Slide side wall into position 22 22 Lift and place back wall 19 19 Installation Data 160304PSL R 160304PSML R 260304PSL R 260304...

Page 7: ...as experience varying degrees of humidity Refer to silicone manufacturer s instructions for additional information related to curing times 27 27 Apply silicone along horizontal and inside vertical edge Slide side wall into position 25 25 Fasten flanges along top of left side wall with fasteners of choice see Pre Installation Planning 12 into each corresponding stud Fasten side vertical flanges to ...

Page 8: ...ng else that could scratch or dull the surface of your Aquatic unit Instead use warm water and liquid detergents or non abrasive cleansers especially those bathroom cleansers recommended for fiberglass 2 To keep your Aquatic bath fixture sparkling clean apply a coat of good quality automotive paste wax or polish and buff to a high shine with a soft cloth or towel Repeat every six months for easier...

Reviews: