Iron -

 Iron is found in many natural waters especially from wells. Iron in water can also result from the corrosion of 

piping in the water supply system, such as cast iron mains or galvanized steel service lines, or galvanized piping in 

the home water system. High iron levels may result in the formation of brown stains in the vicinity of the faucet outlets 

of various fixtures in the home. With whirlpool bathtubs, the staining may be particularly pronounced because the 

aeration action can oxidize iron to a form that settles out on the inside of the tubs, especially noticeable with white 

tubs. If high iron in the water is present, you can also notice rust colored deposits inside your toilet tank or dishwasher. 

If this occurs, you need to contact the water supplier to determine the iron content and/or corrosion potential of the 

water and follow their suggestions for treatment. If your water supply is generated from a well you need to contact the 

water treatment company to test your water and suggest solutions if a problem is present.

 

Manganese -

 Manganese is found in many natural waters especially from wells. High manganese levels may result 

in the formation of small black particles that can stain laundry, especially noticeable with whites such as sheets or 

towels. With whirlpool bathtubs, the formation of small black particles may be particularly pronounced because the 

aeration action in the tub can oxidize manganese to an insoluble form that is especially noticeable with white tubs. If 

high manganese in the water is present, you may also notice black stains on white laundry. If this occurs, you need to 

contact the water supplier to determine the manganese content of the water and follow their suggestions for treatment. 

If your water supply is generated from a well, you need to contact a water treatment company to test your water and 

suggest solutions if a problem is present.

3. 

Treatment

  If you have contacted your water supplier and followed their instructions and you are still having problems, you 

need to increase the frequency of cleaning with low-foaming detergent/bleach starting from monthly purging down 

to using it every other day as required to eliminate your particular problem. The use of certain bath oils, bubble 

bath soaps and bath additives may increase the level of accumulations of bath residue in the whirlpool system. 

More frequent cleaning may be necessary if these products are used in the whirlpool tub. If excess accumulations 

persist, you should discontinue the use of these products. If you have followed the monthly purging instructions and 

still have an excess accumulation of bath residue and desire an alternative cleaning mechanism, we recommend 

SUPER SYSTEMS CLEAN PLUS

 manufactured by Stearns Packaging Corporation to rectify this condition. This may be 

obtained by contacting Aquatic at (800) 945-2726. It is recommended that you follow the instructions provided by 

the manufacturer with the product. Repeated use may be necessary. 

SUPER SYSTEMS CLEAN PLUS

 does not replace  

the necessity to purge your whirlpool system at least once a month with a low foaming detergent and bleach.

WATER QUALITY

Summary of Contents for ACRYLX

Page 1: ...SERIES INSTALLATION AND OWNER S MANUAL TO BE REMOVED FOR USE BY THE OCCUPANT Note Read all instructions before proceeding with installation All specifications are 1 4 and are subject to change withou...

Page 2: ......

Page 3: ...INSTRUCTIONS 11 17 Framing Diagrams 11 Deck Cutouts 12 Framing Installation Procedures 14 Electrical Connections 15 16 Final System Test Clean Up 17 OPERATION INSTRUCTIONS 18 Your whirlpool bathtub w...

Page 4: ...nformation below and reference when contacting the distributor to expedite warranty claims OWNER INFORMATION Model Name Serial Number Purchase Date Distributor AQUATIC Product Registration Information...

Page 5: ...ranty If you have any questions concerning installation operation maintenance or any other aspect of your whirlpool please contact AQUATIC CUSTOMER SERVICE CENTER 800 945 2726 The Troubleshooting Guid...

Page 6: ...er Push the reset button Power should be restored If the GFCI fails to operate in this manner there is a ground current flowing indicating the possibility of an electric shock Do not use this unit Dis...

Page 7: ...rate the whirlpool system if The bathtub isn t filled to required levels above jets You re pregnant until you ve consulted your doctor You re taking medications or drugs that may make you drowsy You r...

Page 8: ...lation system as this may affect the performance or safe operation of the whirlpool and will VOID ALL WARRANTIES 4 For an Aquatic jetted tub supplied with a motor that has an integral pneumatic on off...

Page 9: ...g a Ground Fault Circuit Interrupter GFCI is required See ELECTRICAL CONNECTIONS on pages 15 16 3 It is your responsibility To contact a qualified electrical installer To assure that electrical instal...

Page 10: ...nity toilet etc must not obstruct skirt removal b Island or Pier Installations Provide access panel at motor end See FRAMING DIAGRAMS on page 11 c Sunken Installations Provide access panel in floor or...

Page 11: ...ub Tile 100 Silicone Sealant 1 x 3 Ledger Tile Bed Wood Shim Wall Stud Tub Tile bed 100 Silicone Sealant Tile Tub Alcove Integral Skirted Models ISLANDS ALCOVES OVAL MODELS A 6 x 12 Box outs B Leveled...

Page 12: ...e to match the dotted center line on the template with the center line on the plywood Trace again to outline Quadrant 2 Repeat until the remaining quadrants of the cutout have been traced CORNER MODEL...

Page 13: ...If necessary shim feet until unit just rests on leveled ledges or framework Secure the unit by fastening the bottom feet to the subfloor with any construction adhesive The use of casting plaster or p...

Page 14: ...loor materials To remove skirt panel Simply pry loose at the top corners and pull outward away from frame To reinstall skirt panel Simply set panel in frame bottom side first and push forward Lightly...

Page 15: ...ave the problem corrected by a licensed electrician before using 4 Grounding Motors have a three prong electrical plug A ground should be run from J box receptacle to electrical house panel per code 5...

Page 16: ...atic 16 Elements Series Owner s Manual Installation Guide ELECTRICAL CONNECTIONS Elements Series Whirlpool Component Breakdown Electrical Requirements 120VAC 15 Amp GFCI outlet INSTALLATION INSTRUCTIO...

Page 17: ...n Malfunctions of the pump motor whirlpool controls or the circulating system should be reported to the distributor who supplied the whirlpool tub Clean up 1 Remove all construction residue and foreig...

Page 18: ...l unless water is at least this high 3 Optional remote power switch A separate switch on your bathroom wall may control power to the whirlpool bathtub For your safety it should not be within reach of...

Page 19: ...t water 4 6 tablespoons of low foaming detergent such as liquid Cascade and 24 48 oz of liquid household bleach use lesser amounts shown for 5 foot bathtubs greater amounts for larger bathtubs 3 Run t...

Page 20: ...For soap scum general black grime or algae chlorine bleach may be used with moderate scrubbing In both instances the unit should be rinsed carefully with cold water Scrubbing is never recommended as...

Page 21: ...es of bacteria causing the problem would require lengthy and costly laboratory testing however most experts believe the bacteria responsible is Serratia Marcescens These bacteria thrive on moisture du...

Page 22: ...uble form that is especially noticeable with white tubs If high manganese in the water is present you may also notice black stains on white laundry If this occurs you need to contact the water supplie...

Page 23: ...haft seal requires replacement 1 Contact Aquatic Leaking unions 1 O ring missing or damaged 2 Loose unions 1 Contact Aquatic 2 Tighten unions Vibration noise 1 Tub or tub plumbing is touching tile wal...

Page 24: ...B TEE 8413180FTG FTG 90 DEG 1 2 SPG X 3 8 BARB ADP 8425022FTG 3 8 SB X 1 SPG ADP 8425107FTG A C ELBOW 1 2 LOW PRO 1078 SUCTION LOW PRO 1126XX TEE BULLHEAD 1 X 1 X 11 2 810250FTG FTG 1 CHECK VALVE 8441...

Page 25: ...atic at 800 945 2726 for parts pricing and shipping charges IMPORTANT The following information MUST accompany your order Serial Number Model Number Name Purchase Date and Color BILL TO Name Company A...

Page 26: ...Aquatic 26 Elements Series Owner s Manual Installation Guide...

Page 27: ...ained in accordance with good industry practice and the specific Aquatic directions contained in the Owner s Manual and Installation Guide Write for one if you don t have one EXCLUSIONS These warranti...

Page 28: ...28 Aquatic Customer Service 800 945 2726 www aquaticbath com 8MANELE 07 10 18...

Reviews: