background image

Aquatic 

9

Builders' Choice Owner's Manual & Installation Guide

 INSTALLATION

WARNING - 

When using electrical products, basic precautions should always be followed, including the following:

DANGER - RISK OF ELECTRIC SHOCK. 

Connect only to a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI).

(For built-in and custom units.) Install to permit access for servicing.

1.  Install outlet(s) as shown. The outlet must be a minimum of 6" above the floor and be accessible through  

the access panel. 

2.  Place the bath in the location for installation. Check that the bath is leveled (length and width). A carpenter’s level 

is recommended. If necessary, place shims under support legs. Make 
measurements for framework construction. Remove bath from location.

3.  Construct framework.

•  Ensure that construction and construction materials comply  

with applicable code requirements for the installation site.

•  All framing must be square, level and designed to provide  

structural support.

•  Do not allow tub rim to support any of the bath weight.

4.  An access panel, 16" x 16" minimum, must be provided to allow access to the pump, electrical connections, and 

other accessories.

5.  

ALL MODELS WITH LEVELING FEET

 - The following procedure is recommended for pre-leveled bottoms. Lift unit by 

the rim and place in alcove or framework. If necessary, shim feet until unit just rests on leveled ledges or framework. 
Secure the unit by fastening the bottom feet to the subfloor with any construction adhesive. The use of casting plaster 
or plaster of paris is suggested but not mandatory as a foundation support between floor and bottom of unit to 
suppress noise and give a solid and stable feel for the user.

6.  

WHIRLPOOL & SOAKING TUB MODELS WITHOUT LEVELING FEET

 - (Including island or self rimming units) Just 

before placing unit in alcove or framework, spread a bed of casting plaster or plaster of paris on the floor or subfloor. 
Limit the size of bed to dimensions of bottom. Lift unit by the rim and place in alcove or framework. Press down until 
the tub perimeter rim just rests securely on top of the ledge or framework on all sides. This step is mandatory to prevent 
shifting after installation and for proper operation, drainage and weight distribution. Use a carpenter’s level to check 
that the unit is leveled.

7.  The rim of the bath is not designed to support weight. If finished material is to overlap or contact the bath, the added 

weight must be fully self-supporting.

IMPORTANT: 

If a skirt is to be used, it must be installed at the time of tub installation.

 

[See

 SKIRT INSTALLATION  

PROCEDURES 

on page 10.

]

 Install optional trim parts when all installation has been completed.

 

WARNING

Installation Recommendation

Use two or more people to move 
and install jetted bath. Failure to do 
so can result in back or other injury.

INSTALLATION INSTRUCTIONS

Summary of Contents for Belmont II 4072620

Page 1: ...e subject to change without notice Dimensions listed in inches mm Installer This booklet must be given to the product owner Please add important information below Model _______________________________...

Page 2: ...grams 8 Installation 9 Framing Installation Procedures 10 Electrical Connections 11 12 Final System Test Clean Up 13 OPERATION INSTRUCTIONS Your Whirlpool Bathtub What It Is And How It Works 14 Before...

Page 3: ...he installation and service of your whirlpool should be performed ONLY by a quali ed electrician and plumber AQUATIC Product Warranty Registration Information 8101 E Kaiser Blvd Suite 200 Anaheim CA 9...

Page 4: ...ler and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this ma...

Page 5: ...te the whirlpool system if The bathtub isn t lled to required levels above jets You re pregnant until you ve consulted your doctor You re taking medications or drugs that may make you drowsy You re dr...

Page 6: ...irlpool unit and circulation system carefully before installing WATER TEST the unit before installation If any damages or defects are observed DO NOT INSTALL Repack unit and notify distributor immedia...

Page 7: ...ings spout handles valves etc are to be mounted on the unit be certain that the hot and cold water copper supply lines are located where there is ample room for mounting before setting the unit in pla...

Page 8: ...and trace the ellipse Repeat this step three more times Once the tracing is complete cut out the ellipse The dimensions should be exactly 2 50 smaller than the unit A 6 x 12 150 x 305 Box outs B Leve...

Page 9: ...ary shim feet until unit just rests on leveled ledges or framework Secure the unit by fastening the bottom feet to the sub oor with any construction adhesive The use of casting plaster or plaster of p...

Page 10: ...ry loose at the top corners and pull outward away from frame To reinstall skirt panel Simply set panel in frame bottom side rst and push forward Lightly depress the tabs on the top of the panel while...

Page 11: ...licensed electrician before using 4 Grounding Motors have a three prong electrical plug A ground should be run from J box receptacle to electrical house panel per code 5 Bonding A pressure wire conne...

Page 12: ...Aquatic Builders Choice Owner s Manual Installation Guide ELECTRICAL CONNECTIONS Builders Choice Whirlpool Component Breakdown Electrical Requirements 120VAC 15 Amp GFCI outlet INSTALLATION INSTRUCTIO...

Page 13: ...trician Malfunctions of the pump motor whirlpool controls or the circulating system should be reported to the distributor who supplied the whirlpool tub Clean up 1 Remove all construction residue and...

Page 14: ...he bathtub until the water is at least 3 75 above the highest jet Never operate the whirlpool unless water is at least this high 3 Optional remote power switch A separate switch on your bathroom wall...

Page 15: ...by rotating the face plate of individual jets counterclockwise for more pressure clockwise for less pressure OPERATION INSTRUCTIONS Figure 3 Figure 4 FCC CONSUMER INFORMATION Electrical Installation I...

Page 16: ...Packaging Corporation to rectify this condition This may be obtained by contacting Aquatic at 800 945 2726 It is recommended that you follow the instructions provided by the manufacturer with the prod...

Page 17: ...low all package instructions care fully Wear rubber gloves at all times and avoid contact with eyes skin clothing rugs and furnishings Make sure all residues are rinsed off thoroughly Rubber mats If y...

Page 18: ...of bacteria causing the problem would require lengthy and costly laboratory testing however most experts believe the bacteria responsible is Serratia Marcescens These bacteria thrive on moisture dust...

Page 19: ...ble form that is especially noticeable with white tubs If high manganese in the water is present you may also notice black stains on white laundry If this occurs you need to contact the water supplier...

Page 20: ...water at shaft 1 Shaft seal requires replacement 1 Contact Aquatic Leaking unions 1 O ring missing or damaged 2 Loose unions 1 Contact Aquatic 2 Tighten unions Vibration noise 1 Tub or tub plumbing is...

Page 21: ...Aquatic 21 Builders Choice Owner s Manual Installation Guide BUILDERS CHOICE SERIES REPLACEMENT PARTS MAP...

Page 22: ...IR 4a 8499FTG 5982MANIFOLD 1 AIR CHECK VALVE ASSEMBLY 5a 8078MOTOR PUMP MOTOR 0 75HP 5b 810250FTG TEE BULLHEAD 1 x 1 x 1 5 5c 8150UNION 1 5 PUMP UNION 5d 8409015FTG 1 5 90 DEG ELBOW ST 6a OPTION 8095H...

Page 23: ...on TX 76011 3 The whirlpools and tubs must have been installed and maintained in accordance with good industry practice and the speci c Aquatic directions contained in the Owner s Manual and Installat...

Page 24: ...AQUATIC Fax On Demand System Toll Free 877 618 7024 8101 E Kaiser Blvd Suite 200 Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com 8MANBLD F O D 9008 Rev 8 14...

Reviews: