18 Aquatic
Serenity Owner's Manual & Installation Guide
INSTALLATION INSTRUCTIONS
NON-FREESTANDING MODELS
VARIABLE SPEED AIR BLOWER REMOTE MOUNTING
All models except freestanding models
Designating a Remote Location
The designated location for the blower must not exceed more than 15 feet of pipe and 6 directional changes. Choose a
place as close to the bath as possible to make sure that the system works properly. The chosen place must not be cluttered
and/or dusty and must allow for sufficient air circulation. The blower measures 7” W x 11” L x 6 1/2” H. This space
must not be smaller than 4 cubic feet and must have a ventilation opening not smaller than 2” x 4”. The air around the
blower should be approximately 72°F (20°C) or higher for optimal performance.
• The blower and light control box must be accessible at all times.
• The extension cords must be able to reach the light control box and be routed per local code requirements.
Installing the Blower in a Remote Location
The blower can be installed horizontally or vertically. The blower intake maybe installed up or down. Use PVC 1 1/2” pipe
and adapters only. Whenever possible, use two 45° elbows instead of one 90° elbow to change the direction of your
pipe. Glue all pipe connections along the extension you have added. But DO NOT glue the pipe going into the blower;
use the screw you removed when the blower was removed.
• The blower should be 6” off the floor or from the ceiling and the air intake end of the blower should be at least 4” from
any walls or joists.
• To reduce heat loss, insulate the pipe.
Mount the Light Control Box close to the blower and the AC outlet. Plug in the key pad cable, blower cable, water level
sensor cable and attach the Chromatherapy LED light wires. (See image below.) Now plug into a minimum 15 amp,
120V vac that is GFCI protected.
4’’
Low Voltage
Cord to Keypad
Light Box
6’’
Remote Installation in adjacent space (closet) (example only)
Check Valve
Blower
AC Outlet
Chromatherapy
LED Light
Water Sensor Wires
(Black and Red)
Located by Drain