aquatic Industries, Inc.
17
Operation of the inline maintenance heater is completely automatic. The heater will help maintain the temperature of the
water in the whirlpool. The heater includes the following components.
TherMOsTAT: The “smart Thermostat” requires no adjustment and will automatically maintain the water temperature
at 102
o
F - 104
o
F. If the whirlpool is too warm, simply adjust by adding cold water.
hIgh LIMIT: The heater includes an exclusive “Intelligent high-Limit”. This safety circuit will not “false trip” from hot tap
water. It will only turn the heater off if the thermostat fails. To reset, simply press the red button. If the high-limit trips
frequently, contact Aquatic Industries, Inc.
INDIcATOr LIghT: The light turns on when the heater is operating.
Pressure/vAcuuM swITch: The heater is equipped with a preset pressure or vacuum switch. The pump must be
running with water flowing to the whirlpool to allow the heater to turn on.
warning - Prolonged immersions in hotter water may induce hyperthermia.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body
temperature of 98.6
o
F. The symptoms of hyperthermia include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include (1) failure to perceive heat, (2) failure
to recognize the need to exit the whirlpool, (3) unawareness of impending hazard, (4) fetal damage in pregnant women,
(5) physical inability to exit the whirlpool, (6) unconsciousness resulting in the danger of drowning.
wArNiNg - The use of alcohol, drugs, or medication can greatly increase the risk of fatal
hyperthermia.
OPErATiON of LuxEAir SEriES
jET OPErATiONS (continued):
iNLiNE mAiNTENANCE hEATEr OPErATiNg iNSTruCTiONS:
FuLL SizE PrESSurE-FLO hydrOThErAPy jETS:
12A
12C
12B
• To adjust pressure (see Diagram 12A):
1. grasp the outer ring of the jet.
2. Turn the jet clockwise to increase flow, counter-clockwise to shut off.
• To adjust direction (see Diagrams 12A and 12B):
1. using fingertip, move jet eye to desired location.
• To remove jet (see Diagram 12C):
1. grasp the outer ring of the jet.
2. Turn the jet counter-clockwise, until the jet clicks, then pull.
• To replace or change jet (see Diagram 12C):
1. Insert the jet into jet housing.
NOTE: dO NOT FOrCE.
2. Turn the jet clockwise, past point of resistance, until the jet clicks.
All full-size Pressure-Flo hydrotherapy Jets can be easily interchanged with the hand-
held Jet to customize bathing.