ELECTRICAL INSTALLATION
WARNING:
ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A LICENSED, LOCALLY CERTIFIED ELECTRICIAN, IN
ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND PROCEDURES.
WARNING:
WHEN USING ELECTRICAL PRODUCTS, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING.
DANGER:
RISK OF ELECTRIC SHOCK!
Connect only to circuits protected by a Ground Fault Circuit Interrupter (GFCI). A
GFCI is not supplied, however, we do specify its use. All known code authorities require a GFCI.
Rough-in wiring to junction boxes:
Two 240V, 4 wire, 50 AMP GFCI protected circuit.
See electrical schematics for junction boxes on pages 12 and 13 .
Bonding wire:
Connect a #8 bare copper bonding wire from the pump motor or motors and heater to the cold water
plumbing or other suitable ground. Grounding is required. The unit should be installed by a qualified electrician and
grounded as specified above.
For built-in and custom units, install to permit access for servicing.
INSTALLATION INSTRUCTIONS
NOTE:
BEFORE BATH IS USED, THE AIR-WHIRLPOOL SYSTEM SHOULD BE CLEANED IN ACCORDANCE WITH THE
PROCEDURES ON PAGE 23 OF THIS MANUAL.