OPERATION INSTRUCTIONS
HOTSOAK OPERATIONS
Operation of the inline maintenance heater is completely automatic. The heater will help maintain the temperature of the
water in the tub. The heater includes the following components.
THERMOSTAT:
The “Smart Thermostat” requires no adjustment and will automatically maintain the water temperature at
100
o
F - 104
o
F. Heater comes on at 100
o
F (low limit). If the bath is too warm, simply adjust by adding cold water.
HIGH LIMIT:
The heater includes an exclusive “Intelligent High-Limit”. This safety circuit will not “false trip” from hot tap
water. It will only turn the heater off if the thermostat fails. To reset, simply press the red button. If the high-limit trips
frequently, contact Aquatic
INDICATOR LIGHT:
The light turns on when the heater is operating.
PRESSURE/VACUUM SWITCH:
The heater is equipped with a preset pressure or vacuum switch. The pump must be
running with water flowing to the tub to allow the heater to turn on.
CAUTION:
Before use of the unit, test the GFCI for proper operation. The pump/heater should turn off when the GFCI
“Test” button is pushed.
WARNING - Prolonged Immersions in Hot Water May Induce Hyperthermia
.
Hyperthermia occurs when the internal
temperature of the body reaches a level several degrees above the normal body temperature of 98.6
o
F. The symptoms
of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and
fainting. The effects of hyperthermia include (1) failure to perceive heat, (2) failure to recognize the need to exit the
tub, (3) unawareness of impending hazard, (4) fetal damage in pregnant women, (5) physical inability to exit the tub,
(6) unconsciousness resulting in the danger of drowning.
WARNING - The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia.
BATH-SIDE ON/OFF CONTROLS
The On/Off Electronic Button with Timer is the On/Off Button for the HotSoak
pump/heater system.
1. Fill tub with water at least 2 inches higher than the highest circulation portal cover.
2. Push the On/Off Button once to turn HotSoak on. Water will circulate through
the circulation portals producing a consistent water temperature. The HotSoak
system has a built-in timer and will automatically turn off in approximately
20 minutes.
3. To restart HotSoak after it automatically turns off, simply press the On/Off
Button again.
4. When HotSoak is running, press the On/Off Button to turn HotSoak off.