Aquatic 23
Serenity Owner's Manual & Installation Guide
INSTALLATION INSTRUCTIONS
FREESTANDING MODELS
Key Pad
Receiver
Blower
Flow
One Way Valve
VARIABLE SPEED AIR BLOWER REMOTE MOUNTING
for freestanding models
Designating a Remote Location
The designated location for the blower must not exceed more than 15 feet of pipe and 6 directional changes. Choose a place
as close to the bath as possible to make sure that the system works properly. The chosen place must not be cluttered and/or
dusty and must allow for sufficient air circulation. The air around the blower should be approximately 72°F (20°C) for optimal
performance. The blower and control box must be accessible at all times.
Installing the Blower in a Remote Location
The blower will come attached to the one way check valve, make sure the arrow on the valve is pointing away from the blower.
The blower can be installed horizontally or vertically. The blower intake may be installed up or down. Use PVC 1½” pipe and
adapters only. Whenever possible, use two 45° elbows instead of one 90° elbow to change the direction of your pipe. Glue all
pipe connections along the extension you have added.
The blower should be 6” off the floor or ceiling and the air intake end of the blower should be at least 4” from any walls or
joists. The location of the blower should not be air tight; a gap of 1” is recommended for good air circulation. To reduce heat
loss, insulate the pipe.
Sample Installations:
Key Pad
Receiver
Blower
Flow
One Way Valve
Serenity 10 & 37
Serenity 10 & 37