ELECTRICAL CONNECTIONS
WARNING:
ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED, LOCALLY CERTIFIED ELECTRICIAN,
IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND PROCEDURES.
WARNING:
WHEN USING ELECTRICAL PRODUCTS, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING
THE FOLLOWING.
HOTSOAK
DANGER: RISK OF ELECTRIC SHOCK!
This unit requires one dedicated 20 AMP, 120V GFCI only (Please see
DIAGRAM ON PAGE 12). A GFCI is not supplied, however we do specify its use. All known code authorities require
a GFCI.
BONDING WIRE:
Connect a #8 bare-copper bonding wire from the pump motor/heater to the cold water plumbing or
other suitable ground. Grounding is required.
For built-in and custom units, install to permit access for servicing.
HOTSOAK with CHROMATHERAPY
HotSoak with chromatherapy requires two dedicated 20 AMP, 120V GFCI only (PLEASE SEE DIAGRAM ON PAGE 13).
A GFCI is not supplied, however we do specify its use. All known code authorities require a GFCI.
BONDING WIRE:
Connect a #8 bare-copper bonding wire from the pump motor/heater to the cold water plumbing or
other suitable ground. Grounding is required.
For built-in and custom units, install to permit access for servicing.
CAUTION:
Before use of the unit, test the GFCI for proper operation.