background image

OWNER’S MANUAL

Aquatop’s BREZA AC/DC-PLUS Air Pump is an essential piece of 
equipment for aquarists of all levels. With the included AC power 
supply, the AC/DC-PLUS can be used as a standard aquarium air 
pump, but also offers an ingenious design which combines an AC 
power failure sensor with integral back-up battery power! In the 
unfortunate event of a power outage or when the standard electri-
cal connection is lost, our battery powered air pump automatically 
switches over to back-up battery power when the AC power sensor 
cord is plugged in, providing a temporary lift support system for 
your aquatic creatures. 

The BREZA AC/DC-PLUS’ versatile design also makes it a portable 
air pump, perfect for fish bait buckets or for transporting aquatic 
creatures. The BREZA AC/DC-PLUS Air Pump will help keep your 
fish alive and healthy each day and will protect your aquarium’s 
inhabitants during a power outage, even if you’re not around to turn 
it on.

To guard against injury, basic safety precautions should be observed, 
including the following:

READ ALL SAFETY INSTRUCTIONS BEFORE USE.

DANGER

    To avoid possible electric shock, special care should be taken 

since water is employed around the use of this product. For each of the 
following situations, do not attempt to repair yourself: return the appliance 
to an authorized service facility for service or discard the appliance.

NOTE:

 It is your sole responsibility to verify that the plug and the receptacle  

             are clean and free of moisture and salt buildup  at all times. The   
             receptacle must be free of water, salt,  calcium, magnesium and dust. 
             Failure to do so can cause fire,damage to property, and permanent     
             damage to the product and personal injury not limited to loss of life.

NOTE:

 Before installing the unit, check for any signs of damage to the   

             device. If there are any signs of damage to the device,power cable 
             or plug, do not use and return to place of original purchase.

SAFETY INFO

 

1.   A drip loop must be used with all electrical aquarium devices. A drip 
   loop is a self-made part of the cord hanging below the  receptacle. 
      (See Fig.1).
2.   A GFCI (Ground Fault Circuit Interrupter) should be used in the 
branch circuit supplying all power to water pumps and electrical aquarium 
equipment. If you do not have a GFCI, we strongly recommend having a 
qualified electrician install one prior to operating any aquarium component.
3.   Do not plug into extension cord/power strip.
4.   Use this product for its intended use only.
5.   Never yank or pull the cord from the electrical outlet.
6.   Do not operate if the plug or wire is damaged.
7.   Verify that hands are dry prior to disconnecting the power.
8.   To reduce the risks of electrocution, keep all connections dry.
9.   For indoor use only when using AC power supply.
10. In case of product malfunction In the event of product malfunction 
      return  the unit to the vendor of original purchase.
11. Check device for any signs of damage before use.
12. Do not use soaps or detergents when cleaning this device.
      Thoroughly clean and rinse with warm water and make sure the 
       device is completely dry before connecting. 
13. Keep this product away from children.

1

INTRODUCTION

When used with AC power:

Standard Air Pump Mode:

A. Plug the power sensor cord into section B shown in Figure 2, then   
    plug the other end into a power outlet.  Once the LCD screen is lit  
    up, the display will show ON (See Figure 3, #3). The air pump  
    will begin pumping air at the maximum air output volume (Default  
    Setting). Touch and hold the power key for 2  seconds to turn OFF  
    the unit while the LCD screen is lit up.The air pump will stop, and   
    the power will be turned OFF.
B. As shown in Figure 3, #7 & 8, the +/- keys can be used to control   
    the air output volume with a total of 18 intensity levels depending  
    on the users’ requirements. 

Emergency Back-up Mode:

Plug the power sensor cord into section B shown in Figure 2, then 
plug the other end into a power outlet. The air pump will 
automatically power ON. Touch the power key once to turn the unit 
off (See Figure 3, #4). The air pump will automatically enter 
Emergency Back-up Mode in which there will be no air output at all. 
In the unfortunate event of a power outage or when the standard 
electrical connection is lost, the air pump automatically switches over 
to back-up battery power and will be set at the 15th Output Level 
with Intermittent Mode 2 (Default Setting). 

When used with DC battery power:

Note:

 Please ensure that the rechargeable lithium battery is fully   

           charged before performing the following set-up operations.
A. As shown in Figure 1, touch and hold the power key symbol  
     located on the lower left corner of LCD screen for 
     approximately 2 seconds to turn the unit  ON. Once the LCD  
     screen is lit up, the display will show ON (See Figure 3,  #3). The  
     air pump will begin pumping air at the maximum air output 
     volume (Default Setting). Touch and hold the power key for 2  
     seconds to turn OFF the unit while the LCD screen is lit up. The  
     air pump will stop, and the power will be turned OFF.

PROGRAMMABLE AIR PUMP

WITH BATTERY BACKUP

2

WARNINGS & SAFETY

SET-UP INSTRUCTIONS

3

SET-UP INSTRUCTIONS ( CONT’D )

B. As shown in Figure 3, touch the Mode Key (#9) to select 
    Continuous Mode or Intermittent Mode. There will be no 
     number displayed while in Continuous Mode, while the display 
     will show the numbers 1-4 while in Intermittent Mode 
     (See Fig. 3 #5).
     Intermittent Mode 1: The air pump turns on for 2 minutes, 
    then pauses for 1 minute. 
    Intermittent Mode 2: The air pump turns on for 2 minutes, 
    then pauses for 2 minutes. 
    Intermittent Mode 3: The air pump turns on for 2 minutes,
    then pauses for 4 minutes. 
    Intermittent Mode 4: The air pump turns on for 2 minutes,
    then pauses for 6 minutes.

C. As shown in Figure 3, the +/- keys can be used to control the air   

     

     output volume with a total of 18 intensity levels depending on 
     the users’ requirements. 

Note:

 The screen display will automatically lock after 10 seconds 

           without any activity. To unlock the screen, press any key for 1  

    

           second in order to change the settings, or to power the unit OFF.

Reviews: