Model 2500A225C
26
Rev A
2.8.1.3
Connector J5
Notes:
Lines 3, 4: Su3.3 Vdc via a 10kOhm pull-up resistor
Lines 1-4:
Guaranteed operation up to +30 Vdc
Lines 3, 4:
0 Vdc or +3.3 Vdc
TTL Inputs & OD Outputs: Guaranteed operation up to +5 Vdc
TTL
= Digital
OD
= Open Drain
Indicate NO ACTION STATE for TTL Inputs as HIGH (
H
) or LOW (
L
)
Indicate required TTL output state as HIGH (
H
) or LOW (
L
)
Indicate required OD output state as Floating (
F
) or Grounded (
G
)
Control
Lines
Select Function
input or output
Control States
Fault?
= Yes
General Description
TT
L
In
TTL
Out
OD
Out
Pwr OFF
RF OFF
Pwr ON
RF OFF
Pwr ON
RF ON
J5 – 1
F
G
G
Interlock Contactor
J5 – 2
F
F
G
PS2 On/Off
J5 – 3
G
F
F
PS3 On/Off
J5 – 4
F
F
G
PS4,5,6 On/Off
J5 – 5
J5 – 6
J5 – 7
J5 – 8
J5 – 9
L
PS3 Fault
J5 – 10
L
PS4 Fault
J5 – 11
L
PS5 Fault
J5 – 12
L
PS6 Fault
J5 – 13
L
L
Interlock
J5 – 14
L
L
AC Interlock
J5 – 15
H
Amp fault A1
J5 – 16
H
Amp fault A5
J5 – 17
H
Amp fault A6
J5 – 18
H
Amp fault A7
J5 – 19
H
Amp fault A8
J5 – 20
H
Amp fault A9
J5 – 21
H
Amp fault A10
J5 – 22
H
Amp fault A11
J5 – 23
H
Amp fault A12
J5 – 24
L
L
Thermal fault A1
J5 – 25
L
L
Thermal fault A5
J5 – 26
L
L
Thermal fault A6
J5 – 27
L
L
Thermal fault A7
J5 – 28
L
L
Thermal fault A8
J5 – 29
L
L
Thermal fault A9
J5 – 30
L
L
Thermal fault A10
J5 – 31
L
L
Thermal fault A11
J5 – 32
L
L
Thermal fault A12
J5 – 33
+3.3Vdc
J5 – 34
Ground
Summary of Contents for 0053007
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 2500A225C iv ...
Page 28: ......
Page 70: ...Model 2500A225C 46 Rev A ...
Page 80: ...Model 2500A225C 56 Rev A Figure 4 7 SMA Module Input Figure 4 8 Final Module RF Output ...
Page 82: ...Model 2500A225C 58 Rev A ...
Page 84: ...Model 2500A225C 60 Rev A ...
Page 86: ......