Model 500T8G18
24
Rev B
Command Function
Units
Response
format
RDPRW
Returns reflected power out (W)
watts
Pr=[ ]W
RDPOHID
Returns over forward power warning setpoint (dBm)
dBm
Pohi=[ ]dBm
SPOHID
Sets over forward power warning setpoint (dBm)
dBm
RDPOLOD
Returns under forward power warning setpoint (dBm)
dBm
Polo=[ ]dBm
SPOLOD
Sets under forward power warning setpoint (dBm)
dBm
RDPOHIW
Returns over forward power warning setpoint (W)
watts
Pohi=[ ]W
SPOHIW
Sets over forward power warning setpoint (W)
watts
RDPOLOW
Returns under forward power warning setpoint (W)
watts
Polo=[ ]W
SPOLOW
Sets under forward power warning setpoint (W)
watts
RDPRHID
Returns over reflected power warning setpoint (dB)
dBm
Prhi=[ ]dBm
SPPRHID
Sets over reflected power warning setpoint (dBm)
dBm
RDPRHIW
Returns over reflected power warning setpoint (W)
watts
Prhi=[ ]W
SPRHIW
Sets over reflected power warning setpoint (W)
watts
SYSTEM:ON;
Emulates pressing the System ON button from System OFF ( Exit
Sleep Mode)
SYSTEM:OFF;
Emulates pressing the Power Save button. (Enter Sleep Mode)
RDHTRAUTOOFF
Returns heater auto off delay
hours
SHTRAUTOOFF
Sets heater auto off delay (see Table 3-11)
*IDN?;
Returns the product model number
[ ]
*STA?;
Returns status string (see Table 3-9)
[ ]
*STB?;
Returns status string (see Table 3-10)
[ ]
Table 3-6. Catalog of Status Codes
(The RDSTAT command causes the TWTA to return a string in the form STATUS=[
code
], where [
code
] is
an ASCII number whose meaning is given below)
Status Code
Meaning
0
No command was given.
1
Last command was successful.
2
Last command is in process.
3
Last command failed to complete. Time-out.
10
Last command failed. Invalid command.
11
Last command failed. Data was unparseable.
20
Last set command failed. Data was beyond high limit.
21
Last set command failed. Data was beyond low limit.
22
Last set command failed. Data was out of range
23
Last set command failed. Data was wrong polarity
50
Last command failed. Local system does not have remote enabled.
51
Remote system is not ready to accept commands.
60
Command is not allowed in current system state.
901
Assert error: invalid table argument*
902
Assert error: invalid calibration*
* Please call a service representative if you observe this error.
Summary of Contents for 10012342
Page 2: ......
Page 4: ......
Page 8: ......
Page 12: ......
Page 20: ......
Page 44: ...Model 500T8G18 30 Rev B ...
Page 48: ...Model 500T8G18 34 Rev B ...
Page 50: ...Model 500T8G18 36 Rev B ...
Page 56: ...Model 500T8G18 42 Rev B ...
Page 70: ...Model 500T8G18 56 Rev B ...
Page 72: ......