Model 500A250D
28
Rev A
3.4 CONTROL SYSTEM
3.4.1
A18 Control/Fault Board (Schematic 10042218)
The A12 Control/Fault board consists of one 16-bit microcontrollers and several other ICs that monitor and
indicate the status of the amplifier. Power is supplied using only a single 5-volt power supply. The board
offers the following:
Feature
Quantity
Open drain outputs
4
Digital outputs
6
Digital inputs (5-volt tolerant)
24
Analog outputs
2
2-channel encoder input
1
Inputs for a keypad
6
Display connectors
1
Serial communication jacks
2
3.4.2
A20 Interface Board (Schematic 10020073)
The A20 Interface board connects the remote control ports to the A18 controller.
3.4.3
A17 ALC
The A17 Level Control Assembly performs the following functions:
•
Provides automatic level control of the amplifier’s output when placed in ALC mode.
•
Limits RF input level to the amplifier when forward or reflected power levels exceed specified limits.
•
Drives forward and reflective indicators on the display panel.
3.5 SAMPLE PORTS
The signals appearing at the sample ports produce a level of approximately -10dBm at 500W. Both forward
and reverse signals have the same scaling at this point. The sample ports are measured during final alignment
of the amplifier and a correction table is provided with enough measured points to adequately characterize the
sample ports across the full bandwidth of the amplifier. When used with a power meter, sample ports are
intended to be a general guide to the forward and reverse power being produced. If more accuracy or
calibration is required an external directional coupler is recommended.
Summary of Contents for 500A250D
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ......
Page 22: ...Model 500A250D 4 Rev A ...
Page 25: ...Page 3 500A250D 500 watts CW 10kHz 250MHz Graphs ...
Page 26: ...Page 4 500A250D 500 watts CW 10kHz 250MHz Graphs ...
Page 28: ......
Page 46: ...Model 500A250D 24 Rev A ...
Page 58: ......