59
Sequencer Configuration Testing
Now that we have set up our basic sequence we can
manual test it using the Smart Screen or toggling the
Sequencer Master Switch on the transmitter.
Tap the
[Test]
button to take you to the test screen.
Shown Below.
The
“
Test
”
page gives you manual controls to
test your sequence. You can use this page or the
transmitter to test at any time.
To run the sequence from the
”
Test
”
page, tap
the
[Test Down]
button and the sequencer will
play from the current step to the
(Gear Down)
step. Tap the
[Test UP]
button and the sequencer will play from the current step to the
(Gear Up)
step.
The green indicator in the progress bar at the top of the screen will move, the Step value will change and
the
“
Time To Next Step
”
value will change.
You can tap the
[Pause]
button to pause at any step. Tap
[Test Up]
or
[Test Down]
to play from the
(paused step)
. One of the unique and easy features of the Smooth Flite sequencers is that you can freely
mix and match using the transmitter or the Test buttons. We guarantee that you will find the
[Pause]
button invaluable during setup and testing.
We are almost at the end of the sequencer setup with just a few more features to mention.
Add and Remove Steps —
At factory reset the sequencer will set up with 4 steps. In most cases 4 steps
will be enough to satisfy most sequencing tasks. However for more complexed sequencing tasks each
sequencer can have up to 10 steps. You can add or remove steps from your sequence as required.
To add a step at the end of the sequence tap the
[ADD ST]
button.
To remove the current step tap the
[REM ST]
button .
All steps after the current step will be shuffled forward
one step.
Wait To Next Step
-
Each step has a wait time that
triggers AFTER the servos or air valves have been
actuated and BEFORE moving to the next step.
This feature is designed primarily for air valve devices
or slow linear servos that can take time to move from
one point to the other.
Tap the
‘
Wait To Next Step
”
[+]
and
[
-
]
buttons to
increase or decrease a wait state for the current step.