background image

PY500AC SLIDING GATE OPERATOR

11

through.

Set width of pedestrian mode:

Turn on the second and the third DIP-switch (See Fig.9) to ON position.

Press button 4 to open the gate (see

Verify

Verify

Verify

Verify open

open

open

open direction

direction

direction

direction

section), Wait until the gate travels the

distance according to your requirements (the distance range is 0.3m~1.5m or wait for 3~10 sec.), it is

regarded as ‘the width of pedestrian mode’. Then press the same button/button 4 to stop the gate,

wait for some seconds (1~ 44 sec.). Close the gate by pressing the same button/button 4. Press the

same button again to stop the gate or the gate will stop automatically at its closed position if the limit

switch is reached. After this setup is complete, return DIP-switch 3 to OFF position immediately. Thus

the

width

width

width

width of

of

of

of pedestrian

pedestrian

pedestrian

pedestrian mode

mode

mode

mode

has been set.

If you open the gate with button 4, the gate will stop at the expected position that you have set.

Set

Set

Set

Set auto-close

auto-close

auto-close

auto-close function

function

function

function of

of

of

of pedestrian

pedestrian

pedestrian

pedestrian mode:

mode:

mode:

mode:

Turn on the second and the third DIP-switch (See

Fig.9) to ON position. Press button 4 to open the gate (see

Verify

Verify

Verify

Verify open

open

open

open direction

direction

direction

direction

section), wait some

seconds (3~10 sec.). Then press the same button/button 4 to stop the gate, wait some seconds

according to your requirements (1~44 sec.), this period of time is regarded as ‘auto-close time of

pedestrian mode’. Close the gate by pressing the same button/button 4. Press the same button again

to stop the gate or the gate will stop automatically at its closed position if the limit switch is reached.

After this setup is complete, return DIP-switch 3 to OFF position immediately. Thus the

auto-close

auto-close

auto-close

auto-close

function

function

function

function of

of

of

of pedestrian

pedestrian

pedestrian

pedestrian mode

mode

mode

mode

has been set.

Note: the new width of pedestrian mode has been re-programmed in the device and replaced the

original width you have set in

Set

Set

Set

Set width

width

width

width of

of

of

of pedestrian

pedestrian

pedestrian

pedestrian mode

mode

mode

mode

section.

If you open the gate with button 4, the gate will stop at the new expected position that you have set,

after some seconds as what you have set, the gate will close automatically.

Cancel width / auto-close function of pedestrian mode

Cancel both width and auto-close function of pedestrian mode: Turn on the second and the third DIP-

switch (See Fig.9) to ON position. Press button 4 to open the gate (see

Verify

Verify

Verify

Verify open

open

open

open direction

direction

direction

direction

section). Wait for more than 15 sec.. Then press the same button/button 4 to stop the gate. Wait until

the gate close automatically (45 sec.). Press the same button to stop the gate or the gate will stop

automatically at its closed position if the limit switch is reached. After this setup is complete, return

DIP-switch 3 to OFF position immediately. Thus the width and auto-close function of pedestrian mode

have been canceled.

Summary of Contents for PY500AC

Page 1: ...Sliding Gate Operator User s Manual PY PY PY PY5 5 5 500 00 00 00A A A AC C C C...

Page 2: ...introduction 2 2 Important safety precautions 2 3 Main technical parameters 2 4 Mechanical Installation 2 5 Adjustment 5 6 Wire Connecting 6 7 Turning and operation 8 8 Programming Process 10 9 Mainte...

Page 3: ...ange change change by by by by user user user user 2 2 2 2 Important Important Important Important safety safety safety safety information information information information Carefully read and follow...

Page 4: ...ntrol wires Conduit must be preset into the concrete when it is poured Wires within the conduit shall be located or protected so that no damage can result from contact with any rough or sharp part Con...

Page 5: ...operator and make sure it is lined up with the gate Fig 3 Installation Installation Installation Installation of of of of Rack Rack Rack Rack Fix the three nuts in the same package with rack on the ra...

Page 6: ...ing out of the rails The rails must be installed horizontally Install the limit block as shown in Fig 4 and Fig 5 The spring limit switch and blocks are used to control the position of the gate Releas...

Page 7: ...reful not to use too much force otherwise the release bar will be damaged Open and close the gate manually Note If the gate bumps the mounting post and cannot be electric opened move the gate a few in...

Page 8: ...uring closing the gate will reverse and open immediately The product is not factory equipped with an infrared device the infrared output signal must be N C GND 12V Out I R COM 12V Terminal X2 Infrared...

Page 9: ...W Terminal X7 E W Control board Terminal X6 C C Capacitor V U V U Fig 11 7 7 7 7 Tuning Tuning Tuning Tuning and and and and operation operation operation operation Remote control The remote control...

Page 10: ...control button which has been learned the gate will open the motor rotates clockwise and the LED3 and LED4 is turns on The output voltage between LAMP terminal X4 is AC220V 110V the voltage between V...

Page 11: ...close auto close auto close auto close function function function function has been set Cancel auto close function Turn on the second and the third DIP switch see Fig 8 to ON position Press the remote...

Page 12: ...g to your requirements 1 44 sec this period of time is regarded as auto close time of pedestrian mode Close the gate by pressing the same button button 4 Press the same button again to stop the gate o...

Page 13: ...uto close function of pedestrian mode has been canceled Note the new width of pedestrian mode has been re programmed in the device and replaced the original width If you open the gate with button 4 th...

Page 14: ...mode mode external external external external button button button button switch switch switch switch keypad keypad keypad keypad not not not not supply supply supply supply With each press of the but...

Page 15: ...gn and specification without prior notification 10 10 10 10 Troubleshooting Troubleshooting Troubleshooting Troubleshooting 11 11 11 11 Packing Packing Packing Packing list list list list After receiv...

Reviews: