background image

 

 

5 Before using your stove 

 

Arada stoves are designed to be operated with the fire door(s) closed at all times, apart 

from refuelling (when alight) or cleaning (when cold). 

 

Never leave the appliance unattended for an extended length of time with the 

door open. 

 

Prior to lighting the stove for the first time, please check with the installer that: 

 

Installation and all building work is complete. (Refer to the installation guide.) 

 

The chimney is sound, has been swept and is free from obstruction. 

 

Building Regulations and any local by-laws have been followed during installation. 

 

All firebox liner panels and throat plate are in place. 

 

The chimney draw has been checked and is within specification (between 0.1mb to 

0.2mb, or 10-20 pascals). This ensures your stove will operate predictably and      

efficiently. 

 

A Carbon Monoxide detector is correctly installed in the same room as the  

 

appliance. 

 

Suitable provision for combustion and ventilation air, depending upon Building     

Regulations have been undertaken by the installation fitter. 

 

Consideration must be given for the need for extra ventilation if another heating 

source needing air is to be operated simultaneously. If an extraction fan is proposed 

to be fitted to a connecting area of the house, after the stove has been installed, 

professional advice should be sought from a qualified engineer. 

 

Ensure that you have read and understood these instructions before lighting the fire. 

 

Our YouTube channel, 

www.youtube.com/user/aradastoves 

features a collection of     

videos designed to help you get the best from your Arada stove. 

 

Always wear suitable protective fire gloves when refuelling your stove, such as the Arada 

hot glove supplied with your stove. Always keep the hot glove away from naked flames 

and sparks when re-fuelling the appliance. 

 

We recommend that you light a small fire for the first few days of use to cure the paint 

and allow the castings to relax.   

 

You may hear your stove produce clicking or ticking noises whilst it heats up or cools 

down. This is completely normal and is produced by the expansion and contraction of the 

steel components in your stove when its temperature changes. 

Page 13 

BK 746 Specific  

LAGOM Stove User Guide 

Summary of Contents for Lagom

Page 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK 746 SPECIFIC Rev 01 ISSUE DATE 05 10 2020 EN 13240 2011 A2 2004 Lagom Stove User Guide Lagom...

Page 2: ...ave any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical support department on 44 0 1297 632050 or visit our website ww...

Page 3: ...warnings 2 2 Health and safety 4 Recommended fuels 4 1 Wood 5 Before using your stove 6 Air inlet controls 6 1 Air inlet 6 1 1 Air control location 6 1 2 Air control 7 Lighting your stove 7 1 1 Smoke...

Page 4: ...8 11 Storage cupboard compartment 9 How heat is delivered by your stove 9 1 Radiant heat 10 Care for your Arada stove 10 1 Liners firebricks 10 2 Throat plate 10 3 Fire door seal 10 4 Cracked glass 1...

Page 5: ...rnal Rear Flue Outlet Behind Knock Out Rear Cover NOTE Top rear flue outlets are interchangeable will depend upon installation requirements Fire Door Assembly Fire Door Handle Socket LAGOM Stove User...

Page 6: ...ss LAGOM Stove User Guide Page 6 BK 746 Specific 1 2 Identifying parts terminology of your stove Internal Throat Plates Upper metal lower ceramic Ash Pan Location Below grate area Storage Cupboard Gra...

Page 7: ...E NOTE This additional information is to be read in addition to BK545 Dry Stove Installation Guide 2 1 Stove clearances dimensions Minimum Distance To Combustible Materials A B C D 100mm 100mm 800mm 1...

Page 8: ...l building standards in force Floor protection Minimum dimensions Distances can be increase from stated Stove Protection Plate A B 100mm 257mm Corner installation clearances to combustible materials F...

Page 9: ...LAGOM Stove User Guide 2 4 Stove dimensional drawing BK 746 Specific Page 9 Secondary Primary Air Control External Air Connection 125mm...

Page 10: ...xternal air connection is required for installation then a suitable supply duct of 125mm diameter in metal construction is recommended External Air Connection Rear Default External Air Connection Base...

Page 11: ...um coke or Bituminous house coal must NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Please ensure that the air inlet vent grills to the dwelling are no...

Page 12: ...east 24 months in the case of hard wood We recommend using dry logs with a diameter of 5 8cms and length of 20 25cms If when burning wood you see signs of sticky tar inside the appliance or chimney yo...

Page 13: ...the installation fitter Consideration must be given for the need for extra ventilation if another heating source needing air is to be operated simultaneously If an extraction fan is proposed to be fi...

Page 14: ...e direct air feed ducting requirements NOTE DO NOT COVER OR PARTIALLY OBSTRUCT THE AIR INLET OPENINGS FOR THE APPLIANCE 6 1 1 Air control location The air control regulates the air entering the fire b...

Page 15: ...ce and is located centrally below the fire door Pulling the control lever out achieves the fully open position see Figure 1 Pushing the control lever in will reduce the air or shut down the stove as s...

Page 16: ...quires a good supply of air coming from above the fuel For this reason we open the air inlet fully while igniting the stove then reduce this once the burn is well formed As much as 40 of the heat from...

Page 17: ...r during the transition period i e when the outside temperature is higher than 15o C during rainy and humid days or wind gusts During this period the fireplace stove should be operated with the minimu...

Page 18: ...urning material in the fire bed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel char...

Page 19: ...arts body paint which has turned dusty white is also indicative of such use 8 3 Chimney fires Used in the correct manner with the correct fuel and regular maintenance a chimney fire should never occur...

Page 20: ...Replacement parts Genuine replacement spare parts can be obtained from www aradastovesandspares com You can find a complete list of spares and consumables such as liners grate and throat plates as wel...

Page 21: ...t blackened To remedy this operate the appliance at a fast rate Alternatively when the stove is cold open the door and clean the inside face of the glass with a damp cloth or with glass cleaner www ar...

Page 22: ...ss and less intense the further you move away from the stove This radiated heat is delivered as infrared rays heat the objects they strike It is then these objects such as the chimney breast hearth et...

Page 23: ...ate correctly there is no need to replace them Cracked liners will not in themselves effect the performance of the stove 1 Incline and remove the throat plate 3 2 Incline and remove the side bricks 2...

Page 24: ...rebox and it may fail completely leading to personal injury or a fire You should discontinue use of your stove until it has been repaired You can source replacement glass kits from www aradastovesands...

Page 25: ...er more information about your stove and associated articles Arada Technical Support 01297 632052 technical aradastoves com Arada Stoves Support Site www aradastoves com support Competent Person Schem...

Page 26: ...use The following guarantee periods shall apply in respect of the following Arada stoves The Arada Lagom comes with a 10 year guarantee to the main body The external paint finish carries a one year g...

Page 27: ...ered by this guarantee Firebox linings Grate Fuel retainer Throat plate Gaskets Door glass Seals 9 The guarantee does not cover damage caused by storing or using the stove in a damp environment defect...

Page 28: ...ng Standards offices or a Citizens Advice Bureau If you believe your appliance is not working correctly or it has broken components in the first instance please contact your local retailer or installe...

Page 29: ...6 Minimum Distance to Combustible Materials Single Walled Flue mm 100 Rear 100 Side Weight Packed Kg 123 Nominal Heat Output Wood Kw 4 0 Efficiency Nett 80 5 Mean Flue Gas Temperature C 247 Mean CO E...

Page 30: ...LAGOM Stove User Guide 14 Notes Page 30 BK 746 Specific...

Page 31: ...BK 746 Specific Page 31 14 Additional Notes LAGOM Stove User Guide...

Page 32: ...6 Specific Arada Ltd The Fireworks Weycroft Avenue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050 Email info aradastoves com DATE OF ISSUE 05 10 2020 LAGOM Stove User G...