STOP USING THE APPLIANCE IF YOU SMELL FUMES OR SEE SMOKE
ESCAPING.
If fume emission does persist, the following immediate actions should be taken:
Open doors and windows to ventilate room.
Let the fire die or extinguish and safely dispose of fuel from the appliance.
Check for flue or chimney blockage, and clean if required.
Seek expert advice from your approved installer.
Do not attempt to re-light the fire until the cause of the fume emission has been identi-
fied and corrected.
7.6 Refuelling on to a low fire bed
If there is insufficient burning material in the fire bed to light a new fuel charge, excessive
smoke emission can occur. Refuelling must be carried out onto a sufficient quantity of
glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there
are too few embers in the fire bed, add suitable kindling for ignition to prevent excessive
smoke.
7.7 Typical burn for nominal output
To perform the most efficient burn at the nominal rated output please consult the
specification table at the rear of this manual.
Please note that many factors can effect the nominal output, so the stated weights of fuel
(Seasoned hard wood) are a guide, which is a representation to laboratory test burn
conditions.
LAGOM Stove User Guide
BK 746 Specific
Page 18