Page 21
BK 746 Specific
8.8 Adverse weather conditions
If due to adverse weather conditions your stove does not operate correctly and causes the
stove to emit smoke, do not treat it as a nuisance. This smoke will indicate that carbon
monoxide is being emitted into the room. Extinguish the stove by reducing the firing rate,
open windows and allow the stoves fuel to burn out before closing the windows. The
probable cause is insufficient draw; check flue ways and have the chimney tested for flue
pressure.
8.9 Door glass
The door glass should remain clear during normal burning. However under certain
conditions, such as burning at a low or slow rate, using damp wood or overnight burning,
the glass may become somewhat blackened. To remedy this, operate the appliance at a
fast rate. Alternatively when the stove is cold, open the door and clean the inside face of
the glass with a damp cloth or with glass cleaner (www.aradastovesandspares.com or
Arada dealers).
8.10 Fire door handle and air control slider
WARNING
ALWAYS USE THE HOT GLOVE WHEN USING THE FIRE DOOR HANDLE AND
CONTROL SLIDER LEVER— RISK OF PERSONAL INJURY MAY OCCUR.
8.11 Storage cupboard / compartment
WARNING
NEVER STORE FLAMMABLE LIQUIDS OR COMPRESSED GASES IN THE STORAGE
CUPBOARD — RISK OF EXPLOSION AND PERSONAL INJURY MAY OCCUR.
NEVER STORE COMBUSTIBLE MATERIALS WITHIN THE STORAGE CUPBOARD —
RISK OF IGNITION/FIRE AND PERSONAL INJURY MAY OCCUR.
The storage cupboard door has no handle. To open simply push on the upper right hand
corner. The spring catch will open the door. To close simply push shut and the spring
catch will engage to the latch.
LAGOM Stove User Guide