LAGOM Stove User Guide
Page 8
BK 746 Specific
PLEASE NOTE :
This additional information is to be read in addition to
BK545 ‘Dry Stove Installation Guide’
2.2 Corner Installations dimensions
2.3 Floor protection dimensions
The stove should be installed on this 100% non-flammable floor. Where a combustible
floor is present, a stove protection plate of non –combustible materials should be used.
The following manufactures recommendation should be adhered too, in conjunction with
the relevant local building standards in force.
Floor protection Minimum dimensions
(Distances can be increase from stated)
Stove Protection Plate
A
B
100mm 257mm
Corner installation clearances
to combustible materials
For alcove installation
The ceiling or shelf above
the stove, can be a
minimum of 1200mm above
the appliance top.
C
D
A
B
A
B
C
D
100mm
100mm
400mm
100mm
The stove must be installed on a non-combustible
material plate (cement, brick, stone, ceramic tile,
glass, metal etc ) to protect the floor and possible
fire caused by
ejection of sparks and hot ashes when the
stove door is opened for refuelling etc.
radiated heat caused by stove over firing
spillage of creosote as a result of a chimney
fire.