Installation
VECTOPOWER® VP600....
Modified: 2016.10.12 by Andreas Mangold
Printed: 2016.10.12
VECTOPOWER_VP0x00_xxxA1_Wx_xxx_Installationsanleitung_v1_20_en.doc
87
ARADEX
ARADEX
AG
ARADEX-AG
Ziegelwaldstr. 3
73547 Lorch Germany
Tel.: + 49/ (0)7172/ 9181-0
Hotline:
Fax: + 49/ (0)7172/ 9181-91
E-Mail: info@aradex.com
http:/ / www.aradex.com
+ 49/ (0)700-
6.5.2
VP600-
xxWxxx…..
For devices without additional internal cooling via an air supply from outside, there is no
required direction of installation.
6.6
Electrical connection
DANGER!
The device may only be assembled and electrically connected by author-
ized, EMC-trained specialists in accordance with the applicable regula-
tions, when it is
de-energized
and the
machine is switched off
.
The EMC installation instructions must be observed.
The machine must be secured against restarting!
The device may only be installed and operated when it is in a faultless and
perfect condition.
Modifications to and conversions of the device are not permitted!
Do not lay data and transmission lines in the direct vicinity of lines that
carry high voltage or that are used to switch inductive or capacitive loads.
Do not lay data and transmission lines in the immediate vicinity of motors
or drive amplifiers.
6.7
CAN bus
6.7.1
Connection of several VECTOPOWER
®
devices
Several VECTOPOWER
®
devices can be connected to a single CAN bus. For this purpose,
the CAN terminating resistor must be activated on the respectively last device in the
CAN bus; all other devices must not have a terminating resistor activated.
6.7.2
CAN bus terminating resistor
The terminating resistor can be activated and deactivated via parameters.