3.7.4
ST4 for voltage measurement
A special connector insert must be used for measuring motor terminal voltages or mains
voltages. Please contact your contact partner at ARADEX for this. In this case, a short-
circuit-proof or correspondingly protected line must be used for the external wiring.
Otherwise, if an error occurs, a high current can result in the destruction (normally ther-
mal) of the line and the measuring technology installed in the VECTOPOWER
®
.
For the connectors of the voltage measurement type: A type E insert is installed in the
device, and the mating connector must therefore be type P. Please note!
These connectors can be configured on the Intercontec Produkt GmbH
homepage with the "Configurator". The connector series that is used is
the 923.
The connectors are only suitable for IP66/IP67 protection when plugged in
and mounted correctly.
Suitable accessories are available as a set from ARADEX. See chapter 4.2.
Suitable sealing caps are included in delivery with the VECTOPOWER
®
.
These can be ordered from Intercontec under order number 8B.071.00.