© 2016 Araknis Networks
®
52
Araknis Networks Wireless Access Point
Product Manual
Schedule
17.2 - Gateway Connection Monitor
Use auto ping to help ensure the WAP maintains network connectivity. Configure the WAP to ping the
gateway, and if the ping results fall outside the desired settings, reboot the system.
Figure 42.
Gateway Connection Monitor Settings
Path –
Settings, Schedule, Gateway Connection Monitor
Parameters –
•
Status –
Enable or Disable Auto Reboot.
Default: Disable
•
Gateway IP Address –
Displays the gateway IP address to be pinged, usually the router.
•
Get Current Gateway IP –
Click to pull the current IP address of the gateway.
•
Delay Between Timeouts –
How many seconds the WAP waits to try a new ping after a timeout.
Default: 30 seconds
•
Timeout Attempts Before Reboot –
Number of timeouts that must occur before a reboot occurs.
Default: 10
•
Ping Delay After Auto Reboot –
How many minutes before the WAP pings again after a reboot.
Default: 15 minutes
•
Reboot Attempts –
Number of reboots before WAP stops attempting auto reboot.
Default: 5
Configuration Instructions –
1. Enable Gateway Connection Monitor.
2. Set the desired days and time for reboots to occur.
3. Click
Save
, then
Apply Changes
to enable the new settings.