11.2 Standard Command Set
97
Q = Time quality indicator. may be represented by:
space = locked, maximum accuracy
. = (ASCII 46) Error
<
1 microsecond
* = (ASCII 42) Error
<
10 microseconds
# = (ASCII 35) Error
<
100 microseconds
? = (ASCII 63) Error
>
100 microseconds
Broadcast Mode: NMEA183GLL
Command:
0,nB
0,nB configures the clock to broadcast the National Marine Electronics Association Standard (NMEA-0183)
to broadcast from COM1, where n = the update rate in seconds, from 1 to 9999.
GLL
: Geographic Position, Latitude Longitude
Latitude and Longitude of present vessel position, time of position fix and status.
Response: $–GLL,llll.llll,a,yyyyy.yyyy,a,hhmmss.sss,A*cs
C
Where:
GLL = Geographic Position, Latitude / Longitude
llll.llll = Latitude of position
a = N or S
yyyyy.yyyy = Longitude of position
a = E or W
hhmmss.sss in UTC
A = status: “A” is Active, “V” is Void
*cs = checksum
Broadcast Mode: NMEA183ZDA
Command:
1,nB
1,nB configures the clock to broadcast the National Marine Electronics Association Standard (NMEA-0183)
to broadcast ZDA format from COM1, where n = the update rate in seconds from 1 to 9999. ZDA, time
and date, includes the UTC day, month, year, and local time zone.
Response: $–ZDA,hhmmss.ss,dd,mm,yyyy,
±
xx,xx,*cs
C
Where:
ZDA = Time and date
hhmmss.ss = Time in UTC
dd = Day, 01 to 31
mm = Month, 01 to 12
yyyy = Year
±
xx,xx = Local zone description, 00 to +/- 13 hours and minutes
*cs = checksum
Broadcast Data: ABB SPA MSG
Command:
0,nTB
0,nTB configures the clock to broadcast the ABB SPA format from COM1, where n = the time zone; time
is reported in UTC format for n = 0, and Local format for n = 1.
The ABB SPA time string is a sequence of 32 ASCII characters starting with the characters
>
900WD and
ending with the carriage return character. The letters printed in italics are replaced by ASCII numbers
whereas the other characters are part of the time string.