- 17 -
Operation Mode
3.2 Operation When DC Power is Not Available
Charger
Super
Capacitors
Voltage Converter
PC
12V / 24V
Figure 3-2 SCP Cube Operation During Power Outages
When DC power is not available to the SCP Cube:
•
The supercapacitors start providing power to the connected IPC to maintain
its operation.
•
After the shutdown timeout expires (60 seconds by default), the SCP Cube
starts to hibernate (default) or shutdown your IPC.
If the power resumes during this phase, the countdown timer will
automatically stop counting.
•
During the timeout period, the SCP Cube keeps monitoring if the remaining
capacity is enough for the IPC operation. If the capacity reaches a low limit,
the SCP Cube will hibernate/shutdown the IPC after 10 seconds anyway,
regardless of the shutdown timeout settings.