info@matermacc.it
Use and maintenance handbook
Page 23
5.4. VARIOVOLUMEX
We remind to follow diligently all
the information provided by the
manufacturers inherent to usage,
handling and the transport of the
fertilizers.
Fig. 5.7
FILLING THE TANKS
I The tanks should be filled once you have reached the field.
We recommend you to carry out this operation on flat ground
and with no hindrances. Lower the hoist completely and pull
the emergency brake of the tractor. Make sure the plug of the
discharge hose and the bottom of every distributor is closed,
then fill the tanks.
TANK UNLOADING
Once the work has been completed, it is good practice to
empty the tanks by moving the mouth of an empty bag to
below the tank discharge.
•
Press the stop cap
A
.
•
Move the discharge cap
B
(Fig. 5.8).
A
B
Fig. 5.8
VARIOIVOLUMEX ADJUSTMENT DISTRIBUTOR
The distribution of the fertilizer is made by means of a con-
veyor belt that is fed by means of two slits with a millimetri-
cally adjustable through the
B
ferrule (Fig.5.9).
Acting on the
B
ferrule the opening/closing of the slit is adju-
sted therefore it is possible to dose the quantity of fertilizer
distributed without having to act on the transmission service.
For example the indications are provided in the Adjustment
Table that is placed on all the tanks, with two-figure num-
bers, where the first figure indicates the value to which the
VarioVolumex
A
indicator system must be adjusted, the se-
cond indicates instead the value to which the
B
nut must be
adjusted.
Fig. 5.9
Summary of Contents for Unica Super
Page 2: ......
Page 4: ...www matermacc it Use and maintenance handbook...
Page 16: ...www matermacc it Use and maintenance handbook Page 12...
Page 24: ...www matermacc it Use and maintenance handbook Page 20 F 5 Fig 4 14...
Page 34: ...www matermacc it Use and maintenance handbook Page 30...
Page 36: ......
Page 37: ...Use and maintenance handbook...