Doc No. 740048 

12

 

MODEL 96  

TUBE TO TUBESHEET WELD HEAD  

OPERATION MANUAL 

 

 

6.0 ELECTRODE GEOMETRY AND INSTALLATION 

(Cont’d.) 

 
6. 5 Use this chart to determine a recommended Arc Gap and electrode 

                 Tip Diameter. 

 

Tube/Pipe Wall 

Thickness

 

Recommended  

Arc Gap

 

Recommended Tip 

Diameter

 

0.015”–0.035”(.38 –.89mm) 

0.020”-0.030”(0.50-76mm)

 

0.010”-0.020”  (.25-.50mm) 

0.036”-0.083” (.91-2.1mm) 

0.030”-0.050” (.76-1.3mm)

 

0.020” -0.030” (.50-.76mm) 

0.084”-0.250” (2.1-6.3mm) 

0.050”-0.070” (1.3-1.8mm)

 

0.030”–0.040” (.76- 1.0mm) 

                                                 Fig. 8 
 
 
6.6 Loosen the socket head electrode lock screw in the electrode holder.  
 
6.7 Install an electrode, and be sure it is fully seated and bottomed-out in 
      the holder. Tighten the lock screw. See fig. 9 

 

CAUTION 

DO NOT INSTALL AN ELECTRODE INTO AN OVER-SIZED 

ELECTRODE HOLDER.  

ALWAYS USE THE CORRECT SIZE ELECTRODE HOLDER. 

                  

 

                                                      Fig. 9 
 
 
 
 
 
 

 
 

Summary of Contents for M96

Page 1: ...M96 WELD HEAD OPERATION MANUAL...

Page 2: ...ut notice WARNING The nature of the GTAW process creates some POTENTIAL HAZARDS In accordance with international safety regulations the EXCLAMATION SYMBOL indicates that this equipment is considered H...

Page 3: ...3 2 0 Unpacking 4 3 0 Cable hook up 5 4 0 Rotation speed Calibration 7 5 0 Mandrel installation 9 6 0 Electrode geometry installation 11 7 0 Gas chambers 15 8 0 Nose ring 16 9 0 Shielding gas 17 10 0...

Page 4: ...ectrode maintains a constant electrode to work arc gap distance as it rotates around the joint A gas chamber surrounds the arc and weld joint providing excellent shielding gas coverage This chamber ca...

Page 5: ...ap distance from electrode tip to tube is automatically set The electrode holder is mounted on a pivot arm which swings in or out to accommodate various tube diameters The integral 10ft 3 meter cable...

Page 6: ...on cables may also be used The use of an extension cable does not eliminate the requirement for an adapter If an extension cable is used it is connected between the power supply and the adapter After...

Page 7: ...ket head screw to allow the latch to open far enough to fully seat the two fittings Once the fittings are latched together lightly tighten this screw to prevent accidental disconnection See fig 2 Fig...

Page 8: ...ion See fig 6 Connect the air line to a clean dry air source of 90 120 PSI 6 2 8 3 Bar 4 0 ROTATION SPEED AUTO CALIBRATION Before welding the electrode rotation motor must be calibrated to the power s...

Page 9: ...eld head motor is manually calibrated by creating a weld program that should rotate the electrode 360 degrees ie 1 RPM for a total of 60 seconds 2 RPM for a total of 30 seconds 3 RPM for a total of 20...

Page 10: ...es slow it down by turning the potentiometer counter clockwise CCW Should the rotation be too slow stopping before it reaches its start location rotating less than 360 degrees turn the potentiometer c...

Page 11: ...he mandrel and slide the mandrel shaft into the center hole next to the electrode holder Slowly rotate the mandrel until the threaded end protrudes through the top of the weld head Reinstall the washe...

Page 12: ...25 4mm long electrode properly installed in the electrode holder will stick out the same distance as the feet or tabs on the nose ring which sits on the surface of the tubesheet Use this 1 000 25 4mm...

Page 13: ...0 020 0 030 0 50 76mm 0 010 0 020 25 50mm 0 036 0 083 91 2 1mm 0 030 0 050 76 1 3mm 0 020 0 030 50 76mm 0 084 0 250 2 1 6 3mm 0 050 0 070 1 3 1 8mm 0 030 0 040 76 1 0mm Fig 8 6 6 Loosen the socket hea...

Page 14: ...th the centerline of the electrode either in line with the tube O D or slightly outside the tube O D CAUTION POSITIONING THE ELECTRODE TOO CLOSE TO THE TUBE I D CAN CAUSE THE WELD PUDDLE TO ROLL INTO...

Page 15: ...EOMETRY AND INSTALLATION Cont d Fig 10 6 11 Once the electrode is positioned properly you can measure the distance across the electrode and the mandrel using a veneer caliper or other accurate measuri...

Page 16: ...schedule development as it allows the operator to see the weld puddle being formed is available as an optional accessory 7 1 To remove the chamber first release the two side latches and remove the no...

Page 17: ...tubesheet The nose ring that comes standard with the head is considered a generic nose ring and can be used for multiple applications Shown in Fig 12 For applications that require higher levels of pur...

Page 18: ...shielding gas used is Argon Gas mixtures of 95 Argon 5 hydrogen or 75 helium 25 argon are sometimes used to achieve deeper penetration Consult the factory for recommendations The Model 96 is designed...

Page 19: ...nternals Although you may not be storing the adapter and or extension cables leave them hooked up to the weld head when purging out the water 10 1 To drain the coolant from the weld head and cables us...

Page 20: ...welded cleanliness of the materials being welded is of upmost importance Dirt oil paint hydraulic fluid oxidation or any other contaminant must be removed from both the tube and the tubesheet prior t...

Page 21: ...04 0 68 0 74 I D 17 3 18 8mm 13961000 06 0 74 0 80 I D 18 8 20 3mm 13961000 09 0 80 0 84 I D 20 3 21 3mm 13961001 08 0 83 0 88 I D 21 1 22 4mm 13961001 02 0 88 0 93 I D 22 4 23 6mm 13961001 01 0 92 0...

Page 22: ...gs are designed for specific tube sizes tube spacing and tube pattern square or tri pitch Please contact the factory for recommendations Extension Cables The use of an extension cable does not elimina...

Reviews: