SET-UP AND SAFE OPERATING PROCEDURES
89210000
Problem
Possible Cause
Possible Remedy
Open circuit voltage not
displayed on control panel
“DC Volts” meter
DC power source (welding
power source) not energized
Turn on power source
“Signal Wire” between
contactor and workpiece
unattached or not functioning
Check signal wire
continuity between
contactor and workpiece. If
wire is defective, replace.
Contactor unit in high
temperature shutdown
Allow contactor unit to cool
check fan and filter
DC power cables improperly
attached or not functioning
(damaged)
Repair/replace cables
Connector(s) J4/J5/J6
improperly or not firmly
connected on MCCB*
Check connector(s) for
solid, proper fit
Break in interconnect cable
which links control panel to
contactor
Repair/replace interconnect
cable
Defective “DC Volt” meter
Check/replace meter
Wrong polarity. Straight
polarity, the “DC Volt” meter
reading will be reversed
Connect power cables to
power source and ground
for reverse polarity
Start sequence shuts down
when arc is struck
Inherent starting characteristics
of the DC power source (welding
power source)
Use “No Current Detect”
toggle switch located on
MCCB
Defective MCCB
Replace MCCB*
Low arc voltage setting
Increase arc voltage on either
power source (CP) or control
panel (CC)
Trouble Shooting Guide