Small arc definition:
0 mmpm< cutting speed <2000mmpm small arc=5mm
2000 mmpm< cutting speed <4000mmpm small arc =10mm
4000 mmpm< cutting speed <6000mmpm small arc =15mm
6000 mmpm< cutting speed <8000mmpm small arc =20mm
8000 mmpm< cutting speed <10000mmpm small arc =25mm
10000mmpm< cutting speed <12000mmpm small arc =30mm
12000mmpm< cutting speed <15000mmpm small arc =35mm
Flame adjusts time: the whole time for the system accelerates from its start speed to
the expected cutting speed.
Plasma adjust time: when plasma cutting , from the time the motor starts to the time
when the motor is up to the cutting speed.
Emergency STOP Time: When encounter Emergency Stop input, the time for
dropped from the current speed to zero.
Start Speed: the system’s speed when it began to start. Generally do not have to
start from 0 , motor will allow a start speed.
Max Coordinate: The maximum positive coordinate which the machine can reach
horizontally. Its unit is mm(millimeter). If current coordinate exceeds the value, the
system will stop running.
Min Coordinate: The minimum negative coordinate which the machine can reach
horizontally. Its unit is mm(millimeter). If current coordinate is less than the value, the
system will stop running.
7.6 Parameter Import
In the parameter configuration interface, press F6 to import the parameters. The
parameters should satisfy two conditions: