47
Step 4:
It will switch to component operation step when Display Off button is pressed.
When the Eco-Fuzzy button is pressed, components can be selected in forward direction, and when Quick Cool button is
pressed, components can be selected in reverse direction. The selected component can be activated/deactivated with Frz
Set button. When "Co" is made "1", the compressor is operated. When "Co" is made "0", the compressor is stopped.
Notes:
Sensor display step can be activated by pressing Display Off button twice.
While none of the components are activated, pressing Alarm Off button will activate FF Fan and Frz
Fan together.
Component
selection-
reverse
Closing active
components
Component
opening/closing
FF Fan and Frz Fan
operation with single
button
Switching to
component drive
step
Step 6:
When "Io" is made "1", ionizer will operate.
When "Io" is made "0", ionizer will stop.
Step 5
: If "rE" is made "1", defrost heater will operate.
When "rE" is made "0", defrost heater will stop.
Component
selection-
forward
Step 7
: When "FO" is made "1", FF heater will operate.
When "FO" is made "0", FF heater will stop.
Step 8:
When "FF" is made "1", FF fan will operate.
When "FF" is made "0", FF fan will stop.
Termination of Service Mode:
Service mode is finalized
after 30 minutes or after a power outage.
Step 9
: When "rF" is made "1", FRZ fan will operate.
When "rF" is made "0", FRZ fan will stop.