49
13
ERROR CODES
FRZ Air Sensor Error:
On the display, E and 0 illuminate alternately with set values and warning flashes;
warning is given by the buzzer. The compressor is operated in ON mode for 35min,
and OFF for 25min.
Defrost Sensor Error:
On the display, E and 1 illuminate alternately with set values and warning
flashes; warning is given by the buzzer. The heater operates for 20min. in
freezer defrost state.
FF Air Sensor Error:
On the display, E and 3 are illuminated alternately with
set values and warning flashes;
The compressor is operated in ON mode for 35min, and OFF for 25min.
Heater Failure:
On the display, E and 4 illuminate alternately with set values and warning
flashes; warning is given by the buzzer.
FF Eva Sensor Error:
On the display, E and 2 illuminate alternately with set values and warning flashes;
warning is given by the buzzer.
High Temperature Error:
Warning icon is illuminated on the display.
Set values continue to be displayed.