72-DVT30N-2
25
ELECTRICAL CONNECTIONS, FAN SYSTEM
WARNING: Before starting, make certain the power supply is turned OFF.
The 72
-
DVT30N
-
2 comes complete with a temperature activated fan and rheostat installed and
wired to an internal junction box. The heat sensor is factory set to close the circuit to the fan
speed control at 110
0
F (43
0
C) and will turn off the fan when the temperature falls below 80
0
F
(27
0
C).
Have a qualified electrician run a 120VAC supply line to the lower left side of the fireplace
before installing the appliance. There should be
18” (460
mm) of the supply line free for ease of
connection to the appliance. Connect the electrical supply line to the appliance at the same
time the gas line is being connected to the appliance.
NOTE:
This appliance, when installed, must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70.
Open the bottom (louver) grill and undo the 2 screws holding the control panel. Run the line into
the left side of the appliance through the hole in the rear of the junction box and hold with a
standard
7/8” (22
mm) clamp. Connect the (black) supply conductor to the free black conductor
from the speed controller with a marrette type wire connector. Connect the
‘
neutral
’
white
supply conductor to the free white conductor from the fan with a marrette
-
type wire connector.
Connect the
‘
ground
’ (
green or bare) conductor to the ground screw in the junction box.
Replace the junction box cover the control panel and fasten with the 2 screws. A BX connector
or other suitable approved wiring strain relief must be installed on the junction box.
WIRING DIAGRAM
MO
SPEED
CONTROL
110ºF (43ºC) N.O.
THERMAL SNAP
SWITCH
CONVECTION BLOWER
LINE
GROUND
NEUTRAL
To Appliance Body
120 VAC
white
black
SPEED
CONTROL
LINE
GROUND
NEUTRAL
110ºF (43ºC) N.O.
THERMAL SNAP
SWITCH
CONVECTION BLOWER
black
white
black
green