30
S25 Data Terminal Ready Delay
When Modem is on-line, it will ignore a Data Terminal Ready signal lasting less
than the value of this register. In this mode, the values for this register are 0 to
255 in hundredths of a second, and the default value is 0.05 seconds. If you
will be entering synchronous mode after dialing asynchronously, this register
determines how long the modem waits before looking for the Data Terminal
Ready signal. This lets you detach the asynchronous terminal and connect a
synchronous terminal while remaining in the Data Mode. The default value is 5
Range: 0-255
Default: 5
Units: 0.01 seconds
S26 Request To Send-to-Clear To Send Delay
This register affects synchronous operation only and applies only when you
are using the &R0 command. This register determines how long the modem
waits to turn on the Clear To Send signal after a Request To Send OFF-to-ON
transition in 10 ms increment. The default value is 1.
Range: 0-255
Default: 1
Units: 0.01 seconds
S29
Bit Value Function
0-4 Mapping to AT*I
5-7 Mapping to AT&U
S30 Inactivity Timer
S30 specifies the length of time (in minutes) that the modem will wait before
disconnecting when no data is sent or received. This function is only applicable
to buffer mode.
Range: 0-255
Default: 0
Units: minutes
S45 Timer to Control Sleep Mode
This command displays the number of seconds of inactivity (no characters
sent from the DTE, no RING) in the off-line command state before the modem
places itself into standby mode. A value of zero prevents standby mode.
Note:
If a number between 1 and 4 is entered for this register, it will set the
Summary of Contents for 5634PCV