33
Parameters: 0, 1, 8
Default: 0
Command options:
+FCLASS = 0 Select data mode.
+FCLASS = 1 Select facsimile class 1.
+FCLASS = 8 Select voice mode.
+FTS = <n> Stop transmission and pause
+FTM = <m> Transmit FAX Data
This command causes the modem to transmit data at the modulation specified
by <m>. The following table shows the values you can enter for this command
and the meaning of those values.
+FTM = 3 V.21 Channel2 300
+FTM = 24 V.27ter 2400
+FTM = 48 V.27ter 4800
+FTM = 72 V.29 7200
+FTM = 96 V.29 9600
+FTM = 73 V.17 7200
+FTM = 74 V.17 (short train) 7200
+FTM = 97 V.17 9600
+FTM = 98 V.17 (short train) 9600
+FTM = 121 V.17 12000
+FTM = 122 V.17 (short train) 12000
+FTM = 145 V.17 14400
+FTM = 146 V.17 (short train) 14400
+FRM = <m> Receive FAX Data
This command causes the modem to receive data at the modulation specified
by <m>.
+FRM = 3 V.21 Channel2 300
+FRM = 24 V.27ter 2400
+FRM = 48 V.27ter 4800
+FRM = 72 V.29 7200
+FRM = 96 V.29 9600
+FRM = 73 V.17 7200
+FRM = 74 V.17 (short train) 7200
+FRM = 97 V.17 9600
+FRM = 98 V.17 (short train) 9600
Summary of Contents for 5634PCV
Page 1: ...1 5634 PCV User s Manual ...