10

•  Press the MODE button to go back or to meet the waiting time to exit the setup menu.

The tables on page 13 indicate the operating mode and DMX value. The ARCPOD36FC is equipped with 

3-pole XLR connections.

3.10 DMX ADDRESSING

To able to operate the ARCPOD36FC with a light controller, adjust the DMX start address for the first a DMX 

channel. If e. g. address 33 on the controller is provided for controlling the function of the first DMX chan-

nel, adjust the start address 33 on the ARCPOD36FC. The other functions of the light effect panel are then 

automatically assigned to the following addresses.

An example with the start address 33 is shown below:

Number of

DMX channels

Start address 

(example)

DMX Address 

occupied

Next possible start 

address for unit No. 1

Next possible start 

address for unit No. 2

Next possible start 

address for unit No. 3

4

33

33-36

37

41

45

6

33

33-38

39

45

51

10

33

33-42

43

53

63

.  .  .  .  .  .  .  .  .  .  .  .  

DMX512 Controller

DMX Address: 33

DMX Address: 45

DMX Address: 37

DMX Address: 41

Fig.5 - Example 4 DMX channels configuration

Summary of Contents for 22-00030

Page 1: ...MANUALE UTENTE USER MANUAL IT EN ARCPOD36FC WASH LIGHT ...

Page 2: ...rziale per propri scopi commerciali è vietata Al fine di migliorare la qualità dei prodotti la Music Lights S r l si riserva la facoltà di modificare in qualunque momento e senza preavviso le specifiche menzionate nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it ...

Page 3: ...llazione 2 1 Montaggio 3 Funzioni e impostazioni 3 1 Funzionamento 3 2 Impostazione base 3 3 Struttura menu 3 4 Auto Show 3 5 Static color 3 6 Manual color 3 7 Modalità Master Slave 3 8 Collegamento 3 9 Modalità DMX 3 10 Indirizzamento DMX 3 11 Collegamenti della linea DMX 3 12 Costruzione del terminatore DMX 3 13 Canali DMX 3 14 Funzioni dispositivo 3 15 Attivazione password 4 Manutenzione 4 1 Ma...

Page 4: ...ai 45 C Evitare che nell unità penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unità Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al più vicino centro di assistenza tecnica autorizzato Se si desidera eliminare il dispositivo definitivamente consegnarlo per lo smaltimento ad un istituzione...

Page 5: ... lampade tradizionali Sistema di sintesi colore miscelazione 4in1 RGBW per controllo di tonalità saturazione e temperatura colore Preset temperatura colore bianco 3200K 10000K Angolo di proiezione 15 25 45 opzionali Angolo di campo 22 Durata media diodi LED 50 000 ore Funzionamento ed elettronica Diverse configurazioni DMX disponibili 4 6 10 canali per controllo avanzato o semplificato 4 canali RG...

Page 6: ...n qualsiasi orien tamento Alimentazione 100 240V 50 60Hz Output alimentazione per connessione di più unità in serie fino a 6 proiettori a 230V Consumo ad emissione massima 235W Peso 16 66 kg Dimensioni LxAxP 579x338x115 mm Fig 1 Diagramma di luminosità Disegno tecnico 579 338 115 Illuminance at a Distance 15 1 0m 0m 3 0m 5 0m 7 0m 10 0m 0 26m 0 78m 1 31m 1 84m Lux Center Beam Angle 15 Beam Width 8...

Page 7: ...di montaggio 3 DMX IN XLR a 3 poli 1 massa 2 DMX 3 DMX 4 STAFFA DI MONTAGGIO 5 PANNELLO DI CONTROLLO con display e 4 pulsanti per accesso e gestione delle diverse funzioni 6 DMX OUT XLR a 3 poli 1 massa 2 DMX 3 DMX 7 POWER OUT output alimentazione per connessione di più unità in serie 1 2 4 3 5 6 7 1 3 ELEMENTI DI COMANDO E COLLEGAMENTI Pannello Posteriore ...

Page 8: ...abilità sufficiente e supportare almeno 10 volte il peso dell unità Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza Fissare il proiettore attraverso l apposita staffa 2 ad una collocazione idonea È assolutamente necessario assicurare il proiettore contro la caduta utilizzando un cavo di sicurezza in particolare collegare il cavo in un punto adatto in modo che la cadut...

Page 9: ...resa comandata da un interruttore 3 2 IMPOSTAZIONE BASE l ARCPOD36FC dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 4 Fig 4 Funzione dei tasti MODE UP DOWN ENTER Per scorrere il menu principale o tornare ad una opzione del menu precedente Per scorrere attraverso le diverse funzioni in ordine discendente o aumentare il valore della funzione stessa Per...

Page 10: ...TRUTTURA MENU MENU 1 4CH ð d001 d512 2 6CH ð d001 d512 3 10CH ð d001 d512 4 C ð C1 C15 5 P ð P1 P5 6 S ð S001 S100 7 U ð r ð 000 255 g ð 000 255 b ð 000 255 W ð 000 255 8 dIM ð OFF dIM1 dIM2 dIM3 9 teMP ð 10 PASS ð On OFF ...

Page 11: ...lanciamento personalizzato dei colori rosso verde blu e bianco far riferimento alla seguente procedura Premere il tasto MODE fino a quando sul display non appare U quindi premere il tasto ENTER per confermare Selezionare il colore r g b W attraverso i tasti UP DOWN Per confermare premere il tasto ENTER Utilizzare i tasti UP DOWN per impostare il valore desiderato 000 255 Premere il tasto ENTER per...

Page 12: ...impostare l indirizzo di start DMX per il primo canale DMX Se per esempio sull unità di comando è previsto l indirizzo 33 per coman dare la funzione del primo canale DMX si deve impostare sull ARCPOD36FC l indirizzo di start 33 Le altre funzioni del pannello saranno assegnate automaticamente agli indirizzi successivi Segue un esempio con indirizzo 33 di start Numero canali DMX Indirizzo di start e...

Page 13: ...asmettere in modo affidabile i dati di controllo DMX Collegare l uscita DMX del controller con l ingresso DMX della prima unità Collegare quindi l uscita DMX con l ingresso DMX della successiva unità l uscita di quest ultima con l ingresso di quella successiva e via dicendo finchè tutte le unità sono collegate formando una catena Per installazioni in cui il cavo di segnale deve percorrere lunghe d...

Page 14: ...0 B 0 100 R 0 G 100 0 B 100 R 0 100 G 0 B 100 R 100 G 0 B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 W 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 000 010 011 030 031 050 051 070 071 090 091 110 111 130 131 150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 8 AUTO PRO...

Page 15: ...menu di im postazione Temp Permette di visualizzare la temperatura dell unità Premere il tasto MODE ripetutamente fino a quando sul display non compare teMP 3 15 ATTIVAZIONE PASSWORD Per attivare disattivare la password di accesso Premere il tasto MODE e selezionare PASS quindi premere il tasto ENTER Selezionare On oppure OFF a seconda che si voglia rispettivamente attivare o disattivare la passwo...

Page 16: ...ano in commercio Quindi asciu gare le parti delicatamente 4 2 RISOLUZIONE DEI PROBLEMI Anomalie Possibili cause Controlli e rimedi Il proiettore non illumina Mancanza di alimentazione di rete Dimmer impostato a 0 Tutti i colori impostati a 0 LED difettoso i Scheda LED difettosa Verificarelapresenzadellatensionealimentazione Incrementare i valori del canale dimmer Incrementare i valori dei canali c...

Page 17: ......

Page 18: ...r by any means for any commercial use In order to improve the quality of products Music Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice All revisions and updates are available in the manuals section on site www musiclights it ...

Page 19: ...tions 2 Installation 2 1 Mounting 3 Functions and settings 3 1 Operation 3 2 Basic 3 3 Menu structure 3 4 Auto Show 3 5 Static color 3 6 Manual color 3 7 Master Slave mode 3 8 Linking 3 9 DMX mode 3 10 DMX addressing 3 11 Connection of the DMX line 3 12 Construction of the DMX termination 3 13 DMX control 3 14 Fixture settings 3 15 Activate the password 4 Maintenance 4 1 Maintenance and cleaning t...

Page 20: ...turer directly If the unit is to be put out of operation definitively take it to a local recycling plant for a disposal which is not harmful to the environment Warnings and installation precautions If this device will be operated in any way different to the one described in this manual it may suffer damage and the guarantee becomes void Furthermore any other operation may lead to dangers like shor...

Page 21: ...nal lamps Colour synthesis RGBW Fullcolor mixing for advanced control over color tones saturation and tem perature White temperature presets 3200K 10000K Beam angle 15 25 45 optional Field angle 22 LEDs average life span 50 000 h Electronics and features Several DMX selectable configurations 4 6 10 channels for advanced or basic controlling 4 channels RGBW 6 channels dimmer RGBW strobe 10 channels...

Page 22: ...k more units in a chain up to 6 fixtures at 230V Max power consumption 235W Weight 16 66 kg Dimensions WxHxD 579x338x115 mm Fig 1 Photometric data Technical drawing 579 338 115 Illuminance at a Distance 15 1 0m 0m 3 0m 5 0m 7 0m 10 0m 0 26m 0 78m 1 31m 1 84m Lux Center Beam Angle 15 Beam Width 84865lx 9429lx 3395lx 1732lx 2 63m 848 7lx ...

Page 23: ...ns cable 2 SCREW for the mounting bracket 3 DMX IN 3 pole XLR 1 ground 2 DMX 3 DMX 4 MOUNTING BRACKET 5 CONTROL PANEL with display and 4 button used to access the control panel functions and manage them 6 DMX OUT 3 pole XLR 1 ground 2 DMX 3 DMX 7 POWER OUT connect to supply power to the next unit Rear panel Fig 2 1 2 4 3 5 6 7 ...

Page 24: ...omply scrupulously with all the regulations particularly re garding safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the mounting bracket 2 Always additionally secure the projector with the safety rope from falling down For this purpose fas ten the safety rope at a suitable position so that the maximum fall of the p...

Page 25: ...t which can be switched on and off via a light switch 3 2 BASIC Access control panel functions using the four panel buttons located directly underneath the LED Display fig 4 Fig 4 Functions of the buttons MODE UP DOWN ENTER Used to access the menu or to return a previous menu option Navigates downwards through the menu list and increases the numeric value when in a function Navigates upwards throu...

Page 26: ...NU STRUCTURE MENU 1 4CH ð d001 d512 2 6CH ð d001 d512 3 10CH ð d001 d512 4 C ð C1 C15 5 P ð P1 P5 6 S ð S001 S100 7 U ð r ð 000 255 g ð 000 255 b ð 000 255 W ð 000 255 8 dIM ð OFF dIM1 dIM2 dIM3 9 teMP ð 10 PASS ð On OFF ...

Page 27: ...s the button ENTER Select the color r g b W through the buttons UP DOWN Press the button ENTER to confirm Using UP DOWN button select the desired color value 000 255 Press ENTER button to continue to the next color Continue until the desired mix is obtained Press the MODE button to go back or to meet the waiting time to exit the setup menu 3 7 MASTER SLAVE MODE This mode will allow you to link up ...

Page 28: ... the function of the first DMX chan nel adjust the start address 33 on the ARCPOD36FC The other functions of the light effect panel are then automatically assigned to the following addresses An example with the start address 33 is shown below Number of DMX channels Start address example DMX Address occupied Next possible start address for unit No 1 Next possible start address for unit No 2 Next po...

Page 29: ...MX output of the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit 3 12 CONSTRUCTION OF THE DMX TERMINATION The termination avoids the risk of DMX 512 signals being ...

Page 30: ...0 B 0 100 R 0 G 100 0 B 100 R 0 100 G 0 B 100 R 100 G 0 B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 W 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 000 010 011 030 031 050 051 070 071 090 091 110 111 130 131 150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 8 AUTO PRO...

Page 31: ...eet the waiting time to exit the setup menu Temp Show the temperature unit Press the button MODE so many times until shows teMP 3 15 ACTIVATE THE PASSWORD Enter the KEY mode to select whether the access password is on or off Press the button MODE so many times until show PASS and press the button ENTER to confirm Select On or OFF When the fixture is set as pass On after 30 seconds or turn on the f...

Page 32: ...y For cleaning other housing parts use only a soft clean cloth Never use a liquid it might penetrate the unit and cause damage to it 4 2 TROUBLESHOOTING Problems Possible causes Checks and remedies Fixture does not light up No mains supply Dimmer fader set to 0 All color faders set to 0 Faulty LED Faulty LED board Check the power supply voltage Increase the value of the dimmer channels Increase th...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ... ITALY Phone 39 0771 72190 Fax 39 0771 721955 www musiclights it email info musiclights it ISO 9001 2008 Certified Company ARCHWORK è un brand di proprietà della Music Lights S r l ARCHWORK is a brand of Music Lights S r l company 2017 Music Lights S r l ...

Reviews: