7
ARCPLOT27TRI
2.2 CONNECTION TO POWER
2.3 CONNECTION TO THE CONTROL SIGNAL
For greater stability, it is recommended to use a DMX signal amplifier, if you connect more than 20 units or
the signal cable is greater than 60 m in length.
Fig.3
Fig.4
junction box
junction box
Pin3
Pin3
2
2
1
1
4
4
5
5
SIGNAL IN
SIGNAL OUT
Pins:
•
Pin 1 Shield
•
Pin 2 (black)
•
Pin 3 (white)
•
Pin 4 (green)
•
Pin 5 (red)
Functions:
•
Gnd/0
•
Data input (-)
•
Data input (+)
•
Data output (-)
•
Data output (+)
POWER
junction box
junction box
L (Brown)
N (Blu)
E (Green/Yellow)
L (Brown)
N (Blu)
E (Green/Yellow)
L
L
N
N
E
E