9
ARCHWORK - ArcPod
15Q
DMX ADDRESSING
In order to start controlling the product via DMX, the first step is to select a DMX address, also known
as the start channel, this is the first channel used to receive instructions from a DMX controller. If you
wish to control the product individually, it is necessary to assign a different starting address channel to
each fixture.
The number of channels occupied from the product depends on the DMX mode selected, so always
verify the DMX Mode before start addressing.
If you assign two fixtures the same address, they will be executing the same behaviour. Selecting the
same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control.
DMX addressing is limited to make it impossible to set the DMX address so high that you are left with
-
out enough control channels for the product.
Set the fixture’s DMX address by RDM with the DATAMASTER.
Parameter
PID
GET
SET
DMX_PERSONALITY
0x00e0
X
X
DMX_PERSONALITY_DESCRIPTION
0x00e1
X
X
CURVE
0x0343
X
X
MODULATION_FREQUENCY
0x0347
X
X
IDENTIFY_DEVICE
0x1000
X
FACTORY_DEFAULTS
0x0090
X
X
WBANLANCE_R
0x8200
X
X
WBANLANCE_G
0x8201
X
X
WBANLANCE_B
0x8202
X
X
WBANLANCE_W
0x8203
X
X
FULL ON_Mode(Full On 0:HB, 1:Studio)
0x8217
X
X
7 - RDM FUNCTIONS
The product can communicate using RDM (Remote Device Management) protocol over a DMX512
Networks.
RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open
standard for DMX512 device configuration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting
existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to
and receive messages from specific fixtures.
The PIDs in the following tables are supported in the product.