440 01 1024 01
Specifications are subject to change without notice
51
Manufacturers Number (Mfr No --
See Rating Plate
) ALL Models
Specifications (N9MPD)
N9MPD040F12A
N9MPD050F12A
N9MPD060F12A
N9MPD075F12A
General
Gas Type
Input (Btuh)
Output (Btuh)
Transformer Size (VA)
T’stat Heat Anticipator
Temp. Rise (
o
F/
o
C)
Nat./Propane
40,000
37,000
40
.50
35--65/19--36
Nat./Propane
50,000
46,000
40
.50
35--65/19--36
Nat./Propane
60,000
55,000
40
.50
40--70/22--38
Nat./Propane
75,000
69,000
40
.50
40--70/22--38
Electrical (Volts/Hz)
115/60
115/60
115/60
115/60
Rating Plate Amps
8.6
12.9
10.6
10.1
Gas & Ignition
Gas Type
Nat.
Propane
Nat.
Propane
Nat.
Propane
Nat.
Propane
Gas Valve (Honeywell)
Regulation Type
IgnitionType/Series
VR 8205S
SNAP
Hot Surface
Manifold Press.
(in wc)
Std. Main Orifices (No/Size)
3.5
2/44
10.0
2/55
3.5
2/42
10.0
2/54
3.5
3/44
10.0
3/55
3.5
3/42
10.0
3/54
Furnace Controls
Furnace Control (Type)
Furnace Control
On
(Timed--secs)
Off
Integrated
30
60,100,140,180
Combustion
Flue Outlet Size (Inches)
Std. Outlet Temp (less than)
°
5
′
No Elbows
2
140
o
F/77
o
C
2
140
o
F
/
77
o
C
2
140
o
F/77
o
C
2
140
o
F
/
77
o
C
Blower Pressure
5
′
No Elbows (in wc)
Blower Pressure
40
′
+5--90
°
DWV Elbows (in wc)
Transition Bx Pressure
5
′
No Elbows (in wc)
Transition Bx Pressure
40
′
+5--90
°
DWV Elbows (in wc)
--2.00
--1.90
--0.90
--0.90
----
----
--2.6
--2.3
--1.90
--1.52
--1.10
--1.05
----
----
--2.6
--2.3
Limits & Controls
Rollout Switch (
°
F)
Limit Control Setting (
°
F)
300
250
300
260
300
230
300
240
Standard Pressure Sw. (Part No)
Blower Switch Pressure (Close) (in wc)
Blower Switch Pressure (Open) (in wc)
Transition Switch Pressure (Close) (in wc)
Transition Switch Pressure (Open) (in wc)
1175818
--1.24
--1.05
--0.70
--0.55
1013802
----
----
--2.2
--2.0
1175726
--1.01
--0.86
--0.65
--0.50
1013802
----
----
--2.2
--2.0
High Altitude Pressure Sw. (Part No)
Blower Switch Pressure (Close) (in wc)
Blower Switch Pressure (Open) (in wc)
Transition Switch Pressure (Close) (in wc)
Transition Switch Pressure (Open) (in wc)
1175819
--0.95
--0.80
--0.60
--0.45
1013803
----
----
--2.0
--1.8
1175819
--0.95
--0.80
--0.60
--0.45
1013803
----
----
--2.0
--1.8
Long Vent Kit (Part No)
Pressure Switch (Part No)
Blower Switch Pressure (Close) (in wc)
Blower Switch Pressure (Open) (in wc)
Transition Switch Pressure (Close) (in wc)
Transition Switch Pressure (Open) (in wc)
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
High Altitude Long Vent Kit (Part No)
Pressure Switch (Part No)
Blower Switch Pressure (Close) (in wc)
Blower Switch Pressure (Open) (in wc)
Transition Switch Pressure (Close) (in wc)
Transition Switch Pressure (Open) (in wc)
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
----
Blower Data
Blower Size (D x W)
Motor Amps/RPM
Motor Type/H.P.
Cap. Mfd/Volts
Filter Type & Size (qty.) Permanent -- not supplied
Cool Cap. (Tons) @ .5 in wc L, ML, MHi & Hi
11--8
5.0/960
PSC/
1
/
4
10.0/370
16x25x1
1
1
/
2
,2
11--8
10.0/850
PSC/
1
/
2
7.5/370
16x25x1
1
1
/
2
,2,2
1
/
2
,3
11--10
8.0/1050
PSC/
1
/
2
7.5/370
16x25x1
1
1
/
2
,2,2
1
/
2
,3
11--10
8.0/1050
PSC/
1
/
2
7.5/370
16x25x1
1
1
/
2
,2,2
1
/
2
,3
Gas Conversion Kits 50k & 75k
Nat to Propane
NAHA001LP (1172958*)
Propane to Nat
NAHA001NG (1172960*)
*Order from Service Parts
Gas Conversion Kits for 40k & 60k
Nat to Propane
NAHA003LP (1174906*)
Propane to Nat
NAHA004NG (1174907*)
*
*Order from Service Parts
--